A custom compatible replacement for PSM58N-F2AAGR0BN-1416 must preserve the PROFIBUS scaling boundary, terminal wiring, and 12 mm recessed hollow-shaft fit rather than only matching the 58 mm housing. EncoderWorks configures this model around the 14-bit multiturn and 16-bit singleturn code combination, where wrong scaling, address setting, preset use, or bus termination can cause position overflow, proportional travel error, communication loss, or failed commissioning. Typical production lead time: 15 working days.
This model is used in multiturn absolute position systems where the controller expects a defined PROFIBUS device behavior and a high-resolution binary position value. The replacement must keep the same position relationship, terminal-side bus continuity, rotation direction, and mechanical mounting boundary so that the machine does not require a control-side redesign.


System Limits
The primary system boundary is the PROFIBUS scaling and parameter relationship. PSM58N-F2AAGR0BN-1416 uses a 14-bit multiturn and 16-bit singleturn code combination, so the controller may depend on a specific total measuring range, steps per revolution, preset value, and rotation direction. If the replacement is configured with a lower resolution, wrong total resolution, incompatible Class 2 scaling, duplicated address, or incorrect parameter length, the result can be wrong position scaling, direction reversal, configuration error, communication loss, or a full-stroke proportional error that is difficult to correct mechanically. Bus termination and RS-485 wiring also remain part of the same boundary because unstable data exchange can appear only during commissioning or at higher network speed.
The second boundary is the recessed hollow-shaft and terminal-cover installation. This version uses a 12 mm bore, radial cable exit, and removable terminal compartment, so shaft fit, insertion depth, torque-rest position, cable clearance, and shield termination must match the installed machine. Excessive offset, rigid anti-rotation loading, poor terminal strain relief, moisture at the cover, or shield discontinuity can lead to bearing stress, vibration-related counting instability, bus dropout, water or dust ingress, and early mechanical failure even when the electronic parameters are correct.
Wiring & Installation
Before replacement, confirm the full installed model code, PROFIBUS address, Bus In and Bus Out routing, terminal assignment, controller device class, scaling parameters, preset use, rotation direction, and diagnostic settings. For this 14/16 code combination, the control-side measuring range must be checked before shipment because the same mechanical envelope can still fail if the PLC expects a different resolution structure.
During installation, the hollow shaft should slide onto the machine shaft without forcing the encoder body into alignment. The torque rest should stop housing rotation while allowing small movement so that bearing load is not transferred into the encoder. Keep the bus shield continuous through the terminal compartment, separate PROFIBUS wiring from motor and brake cables, avoid sharp cable bending at the radial exit, and close the terminal cover so that the sealing and grounding boundary are not weakened.
Custom Compatible Solution
- Match the PROFIBUS interface, binary format, 14-bit multiturn range, and 16-bit singleturn resolution
- Preserve scaling parameters, address setting, bus termination logic, preset behavior, and rotation direction
- Adapt the 12 mm recessed hollow shaft, terminal compartment, radial exit, housing envelope, and torque-rest boundary
- Review Bus In / Bus Out routing, shield continuity, terminal sealing, shaft offset, IP exposure, and commissioning risk before shipment
Key Data
| Item | Data |
|---|---|
| Model | PSM58N-F2AAGR0BN-1416 |
| Device type | Multiturn absolute rotary encoder |
| Interface | PROFIBUS, RS-485 |
| Data format | Binary |
| Singleturn resolution | 16 bit, 65536 steps |
| Multiturn resolution | 14 bit, 16384 turns |
| Overall resolution | 14-bit multiturn + 16-bit singleturn code combination |
| Supply voltage | 10–30 V DC |
| Connection | AG, removable housing cover with terminal compartment |
| Cable exit | Radial |
| Shaft / bore | F2A, recessed hollow shaft, Ø12 mm × 30 mm |
| Housing material | N, aluminium, powder coated |
| Option code | 0, no option |
| Expansion code | N, not expanded |
| Protection class | IP65 / IP66 sealing boundary requires confirmation against installed version |
| Key replacement checks | PROFIBUS scaling, address, bus termination, terminal mapping, preset use, rotation direction, hollow-shaft fit, torque-rest preload |