For PSM58N-F1AAGR0BN-1416, EncoderWorks can configure a custom compatible replacement solution around the PROFIBUS Class 2 scaling boundary, terminal wiring, and 10 mm recessed hollow-shaft fit. The failure boundary is defined by the 14-bit multiturn and 16-bit singleturn code combination, preset behavior, rotation direction, address setting, bus termination, and torque-rest loading. Typical production lead time: 15 working days.
This model is used in multiturn absolute position systems where the controller expects a high-resolution binary position value through a PROFIBUS network. A compatible replacement must preserve the installed scaling structure, terminal-side bus continuity, diagnostic behavior, and mechanical anti-rotation method so that the machine can restart without a control-side redesign.


System Limits
The first system boundary is the PROFIBUS Class 2 scaling and parameter relationship. PSM58N-F1AAGR0BN-1416 uses a 14-bit multiturn and 16-bit singleturn code combination, so the controller may depend on a defined total measuring range, steps per revolution, preset value, rotation direction, and diagnostic configuration. If the replacement is configured with the wrong resolution structure, incompatible scaling data, duplicated address, reversed A/B bus wiring, or incorrect parameter length, the result can be configuration error, communication loss, wrong position scaling, direction reversal, data timeout, or a full-stroke proportional travel error.
The second boundary is the 10 mm recessed hollow-shaft and terminal-cover installation. This version combines a smaller bore with a removable terminal compartment, so shaft concentricity, insertion depth, torque-rest position, radial cable exit, shield landing, and cover sealing must be controlled together. Excessive shaft offset, rigid torque-rest preload, poor terminal strain relief, moisture at the cover, or shield discontinuity can create bearing stress, vibration-related instability, bus dropout, water or dust ingress, and early mechanical failure even when the PROFIBUS parameters are correct.
Wiring & Installation
Before replacement, confirm the full installed model code, PROFIBUS address, Bus In and Bus Out routing, terminal assignment, supply voltage, controller device class, scaling parameters, preset use, rotation direction, and diagnostic settings. For this 14/16 code combination, the control-side measuring range and Class 2 parameter set must be checked before shipment because the same 58 mm housing can still fail if the PLC expects a different position structure.
During installation, the 10 mm hollow shaft should slide onto the machine shaft without forcing the encoder body into alignment. The torque rest should prevent housing rotation without acting as a rigid lever that loads the bearings. Keep the PROFIBUS shield continuous through the terminal compartment, separate bus wiring from motor and brake cables, avoid sharp bending at the radial exit, and close the terminal cover so that sealing, grounding, and cable strain relief remain stable during machine operation.
Custom Compatible Solution
- Match the PROFIBUS interface, binary format, 14-bit multiturn range, and 16-bit singleturn resolution
- Preserve Class 2 scaling, address setting, bus termination logic, preset behavior, and rotation direction
- Adapt the 10 mm recessed hollow shaft, terminal compartment, radial exit, housing envelope, and torque-rest boundary
- Review Bus In / Bus Out routing, shield continuity, terminal sealing, shaft offset, IP exposure, and commissioning risk before shipment
Key Data
| Item | Data |
|---|---|
| Model | PSM58N-F1AAGR0BN-1416 |
| Device type | Multiturn absolute rotary encoder |
| Interface | PROFIBUS, RS-485 |
| Data format | Binary |
| Singleturn resolution | 16 bit, 65536 steps |
| Multiturn resolution | 14 bit, 16384 turns |
| Overall resolution | 14-bit multiturn + 16-bit singleturn code combination |
| Supply voltage | 10–30 V DC |
| Connection | AG, removable housing cover with terminal compartment |
| Cable exit | Radial |
| Shaft / bore | F1A, recessed hollow shaft, Ø10 mm × 30 mm |
| Housing material | N, aluminium, powder coated |
| Option code | 0, no option |
| Expansion code | N, not expanded |
| Protection class | IP65 / IP66 sealing boundary requires confirmation against installed version |
| Key replacement checks | PROFIBUS Class 2 scaling, address, bus termination, terminal mapping, preset use, rotation direction, 10 mm hollow-shaft fit, torque-rest preload |