Home › Selection & Replacement › 8.A222.6832.3113 Profibus Encoder with Ø20 mm AX Adapter

8.A222.6832.3113 Profibus Encoder with Ø20 mm AX Adapter

EncoderWorks Team
12 monthsago

For 8.A222.6832.3113, EncoderWorks can provide a custom compatible replacement solution for large-shaft Profibus absolute encoder systems where the key checks are ø20 mm H7 bore fit, torque-arm-side locking-ring access, 70 mm torque-arm preload, Profibus node addressing, and GSD-based scaling. This model should not be treated like the ø16 mm version, because the Profibus encoder body remains the same while the AX adapter bore changes to ø20 mm. Typical production lead time: 15 working days.

This configuration combines a Kübler AX hollow-shaft adapter with a Sendix 5868 absolute multiturn encoder. The AX section provides the ø20 mm hollow-shaft bore, locking ring on the torque-arm side, and 70 mm torque arm, while the encoder body provides Profibus-DP V0 Class 2 absolute position feedback through three radial M12 connectors. Replacement work should focus on shaft fit, clamp access, clamping torque, torque-arm alignment, Profibus node address, GSD configuration, scaling parameters, preset behavior, and shield grounding.

8.A222.6832.3113 Profibus Encoder with Ø20 mm AX Adapter-EncoderWorks
8.A222.6832.3113 Profibus Encoder with Ø20 mm AX Adapter-EncoderWorks

System Limits

The first system limit is Profibus commissioning. The PLC must preserve the correct node address, GSD file, encoder profile behavior, scaling, preset value, counting direction, and diagnostic response. If the encoder appears online but the stored profile or scaling is different, the bus may look healthy while the axis reads the wrong mechanical position.

The second limit is AX mechanical installation. The ø20 mm shaft must match the H7 adapter bore without forcing the clamp, and the locking ring must remain accessible from the torque-arm side. Shaft runout, excessive clamp force, or torque-arm preload can create bearing load, housing movement, or repeatability drift.

The third limit is the AX operating envelope. The adapter is rated IP64 and has temperature-dependent speed limits. High shaft speed, high ambient temperature, or bracket stress can become the practical failure boundary before the Profibus interface itself becomes unstable.

Wiring & Installation

Before replacement, record the Profibus node address, GSD file, scaling parameters, preset value, counting direction, diagnostic behavior, and any set-button function used by the machine. Also record the three radial M12 connector assignments for Profibus bus wiring, supply voltage, ground, and shield connection.

During installation, confirm the ø20 mm H7 shaft fit, keep the locking ring on the torque-arm side, and align the 70 mm torque arm without preload. Route Profibus and power cables away from inverter output wiring, maintain shield continuity through the M12 connectors, and avoid ground loops between the encoder housing, machine frame, and cabinet earth. After startup, verify bus status, actual position value, direction, preset response, diagnostics, torque-arm movement, and repeatability over several machine cycles.

Custom Compatible Solution

EncoderWorks can configure the replacement around the installed shaft and Profibus control system:

  • Match the AX ø20 mm hollow-shaft adapter, torque-arm-side locking ring, 70 mm torque arm, and mounting envelope
  • Preserve Sendix 5868 Profibus-DP V0 Class 2 feedback, GSD setup, scaling, preset, direction, and diagnostic response
  • Adapt the three radial M12 connector layout, 10–30 VDC supply range, bus wiring, and shield grounding
  • Review clamp torque, shaft fit, torque-arm preload, IP64 installation limits, and temperature-speed operating margin

Key Data

ItemData
Model8.A222.6832.3113
Encoder typeAbsolute multiturn encoder with AX hollow-shaft adapter
Encoder bodySendix 5868
InterfaceProfibus-DP V0
ProtocolEncoder protocol Class 2
Supply voltage10–30 VDC
Boreø20 mm H7 hollow-shaft adapter
Locking ring positionTorque-arm side
Torque arm70 mm
Connection3× radial M12 connectors
Adapter protectionIP64
Adapter weightApprox. 3.5 kg
Starting torqueMax. 0.15 Nm at 23°C
Special optionSet button
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

8.A141.6832.3113 Profibus Encoder with Encoder-Side AX Clamp

Previous

8.A221.6832.3113 Profibus Encoder with Ø16 mm AX Adapter

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
1423
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

OCD-PPA1G-0008-B120-CRW:Parallel Encoder 1:1 Replacement

OCD-PPA1G-0008-B120-CRW:Parallel Encoder 1:1 Replacement

EncoderWorks Team
GAMX12-1500-001:GAMX_12//5G59//01500//GPA100 Encoder Technical Solution

GAMX12-1500-001:GAMX_12//5G59//01500//GPA100 Encoder Technical Solution

EncoderWorks Team
OCD-EIC1B-0013-B06S-PRM: The Direct-Replacement Alternative for Profinet Absolute Encoders

OCD-EIC1B-0013-B06S-PRM: The Direct-Replacement Alternative for Profinet Absolute Encoders

EncoderWorks Team
FGHJ40S-1024G-90G-NG/20P Hollow-Shaft Encoder with Isolated EMC Plug Feedback

FGHJ40S-1024G-90G-NG/20P Hollow-Shaft Encoder with Isolated EMC Plug Feedback

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com