We developed a custom solution for the OCD-DPC1B-1213-SB90-H72 model for users who need Profibus communication in a standard industrial housing with straightforward field installation. This configuration uses a 58 mm synchro flange, a 10 mm solid shaft with single-side flat, and 13-bit singleturn plus 12-bit multiturn absolute feedback. Unlike heavy hazardous-area versions, its strength lies in practical bus integration: 3 x M12 connectors, address selection, and terminal resistor switching simplify on-site commissioning. Typical production lead time: 15 working days. The original configuration combines optical sensing, binary code, IP65 protection, and a 10–30 VDC supply range.

Technical Key Parameters

  • Profibus DP interface
  • 13-bit singleturn + 12-bit multiturn resolution
  • Binary code
  • 58 mm synchro flange
  • 10 mm solid shaft, single-side flat, 20 mm length
  • 3 x M12 connector layout
  • Address selector and terminal resistor switch
  • 10–30 VDC supply
  • IP65 protection
  • Max speed 12000 rpm

Custom Solution Photos

OCD-DPC1B-1213-SB90-H72 Profibus Absolute Encoder Custom Solution-EncoderWorks
OCD-DPC1B-1213-SB90-H72 Profibus Absolute Encoder Custom Solution-EncoderWorks

Wiring and Installation Notes

The key integration value of this model is its fieldbus usability in the cabinet and at the machine side. The 3 x M12 arrangement separates supply and bus connections in a way that supports fast replacement and easier troubleshooting. During installation, the solid shaft should be coupled without excessive radial load, especially because the unit is designed for relatively high rotational speed. The built-in address selection and terminal resistor switching should be set before startup so that network topology remains clean and predictable. In retrofit work, this type of configuration is often preferred where technicians want Profibus functionality without using loose flying leads or separate junction assemblies.

Custom Compatible Encoder Solution

  • Custom Profibus replacement solution with matching M12 connector architecture
  • Mechanical adaptation for 58 mm synchro flange and 10 mm solid shaft layout
  • Bus addressing and termination-oriented integration support
  • Signal and installation customization for direct replacement of field-installed units

Lead Time and Custom Development

Typical production lead time is 15 working days. We can support custom work for shaft geometry, connector arrangement, and Profibus integration details based on the existing machine interface.

Key Technical Data

ItemData
InterfaceProfibus
Resolution13-bit singleturn / 12-bit multiturn
CodeBinary
Supply voltage10–30 VDC
MountingSynchro flange, 58 mm
Shaft typeSolid shaft, single-side flat
Shaft diameter10 mm
Connector layout3 x M12
Protection classIP65
Max speed12000 rpm
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

OCD-DPC1B-1212-SB90-H72: Your Custom-Engineered Profibus Absolute Encoder

Previous

OCD-DPC1B-1216-SB90-H72: Configure Your Specific Profibus Absolute Encoder Solution

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
4345
Posts
0
Comments
0
Likes

Articles

CEV65M-03316 5 m Pin-25 DataBus Disable
CEV65S-10089 7 m SUB-D Gray-Code Capture
CEV65S-50004 SUB-D 25-Pin Gray Bit Mapping
CEV65S-10009 Profibus 360-Step Singleturn

Related posts

OCM-DPC1B-0016-F10W-HFZ Posital Absolute Encoders Profibus-DP (Replacement model)

OCM-DPC1B-0016-F10W-HFZ Posital Absolute Encoders Profibus-DP (Replacement model)

EncoderWorks Team
OCD-PPA1G-0008-CA30-PRP:Parallel Encoder 1:1 Replacement

OCD-PPA1G-0008-CA30-PRP:Parallel Encoder 1:1 Replacement

EncoderWorks Team
UCE-AC006-0413-F10W-CRW Analog Absolute Encoder Solution

UCE-AC006-0413-F10W-CRW Analog Absolute Encoder Solution

EncoderWorks Team
CEV65M-01542 Profibus Fieldbus Hood Solution (110-01542)

CEV65M-01542 Profibus Fieldbus Hood Solution (110-01542)

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Absolute Encoder Incremental Encoder Draw Wire Sensors Technical Insights Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Solutions
    • SSI
    • RS485 / Modbus-RTU
    • CANopen
    • Analog
    • Profinet
    • Profibus
    • Parallel
    • EtherCAT
    • EtherNET
    • Incremental
  • Absolute Encoder
  • Incremental Encoder
  • Draw Wire Sensors
  • Technical Insights
  • Contact

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com