A custom compatible encoder solution can be provided for UCE-AC006-0413-F10W-CRW in maintenance, retrofit, replacement, and upgrade projects. This model is built around a current-output analog absolute encoder platform with a clamping flange, a Ø10 mm solid shaft, and a stainless-steel Zone 1 & 21 housing intended for oil and gas duty. Typical production lead time: 15 working days. The engineering goal is to preserve the original 0–20 mA output behavior, shaft-side fit, hazardous-area installation continuity, and field wiring arrangement so that site replacement work remains practical and controlled.
Technical Overview of the UCE-AC006-0413-F10W-CRW Encoder
The UCE-AC006-0413-F10W-CRW is an absolute encoder with a current analog interface. It supports manual setting of the start point and end point through cable or connector, uses magnetic sensing technology, and provides 13-bit singleturn resolution together with 4-bit multiturn resolution. Its multiturn system is based on a self-powered magnetic pulse counter without battery or gear train, and the analog output code is 0–20 mA. The default sensing direction is defined so that the value decreases during counterclockwise shaft rotation when viewed from the shaft side.
From the electrical side, the encoder operates on 8–32 VDC, with typical current consumption of 20 mA at 24 V under no load. Maximum load resistance is 500 Ω, startup time is under 500 ms, analog accuracy at 20 mA is ±20 µA under normal supply conditions, linearity is 0.15%, and settling time is 32 ms for a jump from minimum to maximum value. The unit also includes reverse polarity protection and short-circuit protection.
Mechanically, this version uses a Ø10 mm solid shaft with a single flat and a shaft length of 20 mm. The flange form is a clamping flange, Ø78 mm ATEX. The housing, flange, and panel parts are stainless steel V4A with an uncoated finish. Electrical connection is radial, and the connection format is listed as cable / connector.
Industrial Integration Considerations
For retrofit work, the most important point on this model is the combination of analog current-output continuity and hazardous-area installation suitability. The product page identifies it as a CE + ATEX Zone 1 & 21 oil and gas encoder with IP66/IP67 protection on both shaft and housing sides, so replacement planning should preserve not only shaft fit and signal range, but also enclosure integrity, sealing practice, and application-side installation logic associated with hazardous-duty service.
The analog side also deserves careful review. This encoder provides a 0–20 mA output and supports manual start-point and end-point setting through cable or connector, which means the replacement solution should preserve the original scaling strategy, direction behavior, and zero-setting practice already used by the control system. The page also notes a minimum measurement range of 0–11.25°, a default multiturn range of 16 turns, and scaling capability up to 32768 turns, so application-side range matching should be reviewed carefully during engineering replacement.
Environmental and mechanical durability are also relevant. The encoder is rated for operation from -30 °C fixed and -5 °C flexible up to +70 °C, with humidity tolerance to 98% RH non-condensing, maximum shaft load of 60 N axial and 80 N radial, maximum speed up to 3000 rpm, shock resistance up to 100 g, and vibration resistance up to 10 g. These characteristics support use in sealed industrial feedback systems where environmental tolerance and mechanical stability need to remain consistent after replacement.
Custom Compatible Encoder Solution
A custom compatible encoder solution for UCE-AC006-0413-F10W-CRW should focus on five key engineering points: Ø10 mm solid shaft fit, 0–20 mA analog output continuity, 13-bit singleturn plus 4-bit multiturn measurement structure, hazardous-area installation suitability, and preserved field-setting logic for start point, end point, direction, and zero behavior. This matters because successful replacement depends not only on nominal dimensions, but also on whether the encoder remains aligned with the original measurement range strategy and site installation method.
From the mechanical side, the compatible solution should remain consistent with the Ø78 mm ATEX clamping flange, radial connection direction, and stainless-steel housing platform. From the electrical side, it should preserve the 8–32 VDC supply range, analog current output format, and the existing field wiring logic shown by the connection plan, including power supply, ground, analog output, Set1/Direction, Set2/Zero Set, and shielding. These points should be confirmed during engineering review so the final configuration remains matched to the installed application.
Custom Solution Photos


Lead Time and Custom Development
Typical production lead time: 15 working days.
For custom development, the main checkpoints should include shaft diameter, shaft style, analog output range, start and end point setting logic, radial cable exit, hazardous-area installation requirements, and the original machine-side scaling expectations. Since this model supports manual setting through cable or connector and uses a battery-free multiturn magnetic absolute sensing structure, the final coded configuration should be reviewed from both the mechanical and application-signal sides before release.
Typical Technical Parameters
| Parameter | Specification |
|---|---|
| Encoder Type | Absolute encoder |
| Model | UCE-AC006-0413-F10W-CRW |
| Interface | Analog Current |
| Output Code | 0–20 mA |
| Manual Functions | Start and end point can be set via cable or connector |
| Supply Voltage | 8–32 VDC |
| Current Consumption | Typical 20 mA @ 24 V (no load) |
| Start-Up Time | < 500 ms |
| Max. Load Resistance | 500 Ω |
| Analog Accuracy | ±20 µA @ 20 mA |
| Linearity | 0.15% |
| Settling Time | 32 ms |
| Sensing Principle | Magnetic |
| Resolution Singleturn | 13 bit |
| Resolution Multiturn | 4 bit |
| Multiturn Technology | Self-powered magnetic pulse counter, no battery or gear train |
| Minimum Measurement Range | 0–11.25° |
| Output Resolution | Up to 13 bit over full range |
| Multiturn Range | 16 turns default, scalable up to 32768 turns |
| Sense Signal Default | Value decreases during counterclockwise shaft rotation, front view on shaft |
| Shaft Type | Solid shaft, single flat |
| Shaft Diameter | Ø10 mm |
| Shaft Length | 20 mm |
| Flange Type | Clamping flange, Ø78 mm ATEX |
| Connection Direction | Radial |
| Connection Type | Cable / connector |
| Protection Rating | IP66 / IP67 |
| Operating Temperature | -30 °C fixed, -5 °C flexible to +70 °C |
| Humidity | 98% RH, no condensation |
| Max. Shaft Load | 60 N axial / 80 N radial |
| Max. Speed | ≤ 3000 1/min |
| Shock Resistance | ≤ 100 g |
| Vibration Resistance | ≤ 10 g |
| Approval | CE + ATEX Zone 1 & 21 (Oil+Gas) |
| Housing Material | Stainless Steel V4A |
| Flange Material | Stainless Steel V4A |