We developed a custom solution for the PMG10-SHD.1FP0.36000.A encoder, intended for applications where absolute position feedback must be integrated into Profibus DP systems with combined bus connection and terminal interface for structured wiring architecture. This configuration is based on the PMG10 solid shaft platform with Ø11 mm shaft, EURO flange B10, protection class D, and a combined bus connecting box with additional terminal interface (F version), making it suitable for installations where system wiring, signal distribution, and integration flexibility are critical. It is not a basic encoder for direct wiring only. It is an integration-oriented solution where bus topology, terminal structure, and controller-side configuration determine whether the system operates reliably. Typical production lead time: 15 working days under confirmed configuration.
Custom Solution Photos


Stable operation depends on terminal layout, bus connection integrity, shaft alignment, and structured wiring design.
System Limits
- Incorrect bus topology or address conflict → device cannot communicate correctly
- Improper use of terminal interface → signal routing errors occur
- Parameter mismatch (preset / scaling / direction) → system-level position deviation
This model uses Profibus-DP communication with 13 bit singleturn and 16 bit multiturn resolution, but system limits are defined by integration quality rather than resolution. The combined interface design introduces flexibility but also increases dependency on correct wiring and configuration. Failure is more likely caused by incorrect system integration than by encoder hardware.
Installation and Wiring Constraints
- Supply voltage: 10 to 30 VDC
- Configure Profibus address using rotary switches before commissioning
- Set terminating resistor correctly depending on bus position
- Use terminal interface for structured signal routing, not random distribution
- Keep bus and auxiliary wiring clearly separated
- Apply preset and scaling only within defined control logic
Integration logic:
- A / B = Profibus communication lines
- UB / GND = power supply
- Terminal interface allows structured wiring of additional signals
- Diagnostic supports position and parameter error detection
Failure boundary:
- Address conflict → communication failure
- Incorrect terminal usage → signal mismatch
- Wrong parameter mapping → incorrect position output
System performance depends on integration structure, not just encoder capability.
Replacement and Interface Mapping
- Suitable for systems requiring Profibus encoder with structured wiring integration
- Applicable where combined bus and terminal interface is required
- Not suitable where system wiring or bus configuration cannot be controlled
- Designed for integrated control systems, not standalone applications
Key Data
- Model: PMG10-SHD.1FP0.36000.A
- Type: Absolute encoder, Profibus DP
- Shaft: Ø11 mm solid shaft
- Mounting: EURO flange B10
- Protection class: D, for dusty abrasive environments
- Supply voltage: 10 to 30 VDC
- Interface: Profibus-DPV0/V2
- Transmission rate: 9.6 to 12000 kBaud
- Singleturn resolution: 13 bit
- Multiturn resolution: 16 bit
- Initializing time: ≤500 ms
- Max speed: ≤6000 rpm
- Protection: IP66 / IP67
- Operating temperature: -40 to +85 °C
- Connection: Bus connecting box + terminal interface (F version)