EncoderWorks EncoderWorks
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About
Home › Selection & Replacement › PMG10-SHD.13P0.36000.A Absolute Profibus Encoder High Resolution

PMG10-SHD.13P0.36000.A Absolute Profibus Encoder High Resolution

EncoderWorks Team
6 monthsago

We built a custom solution for the PMG10-SHD.13P0.36000.A encoder, intended for applications where high-resolution absolute position feedback must remain stable over Profibus DP in abrasive industrial environments. This configuration is based on the PMG10 solid shaft platform with Ø11 mm shaft, EURO flange B10, protection class D, using Profibus-DPV0, 13 bit singleturn, and 16 bit multiturn structure. It is not a basic bus encoder for coarse positioning. It is a high-resolution networked feedback device where parameter scaling, bus stability, and controller-side interpretation determine whether the position value remains usable. Typical production lead time: 15 working days under confirmed configuration.

Custom Solution Photos

PMG10-SHD.13P0.36000.A Absolute Profibus Encoder High Resolution-EncoderWorks
PMG10-SHD.13P0.36000.A Absolute Profibus Encoder High Resolution-EncoderWorks

Stable high-resolution feedback depends on shaft alignment, bus connecting box integrity, address setting, and correct Profibus configuration.

System Limits

  • Wrong scaling or preset logic → high-resolution position value becomes meaningless at system level
  • Incorrect address or bus termination → communication stability is lost
  • Controller-side parameter mismatch → fine resolution cannot be used correctly

This model provides 13 bit singleturn resolution (8192 steps per revolution) and 16 bit multiturn resolution (65536 revolutions), but high resolution does not guarantee usable precision by itself. The system bottleneck is not the magnetic sensing method. It is whether the controller reads, scales, and applies the data correctly over Profibus. The encoder supports programmable steps per revolution, number of revolutions, preset, scaling, and rotating direction, so the real failure boundary is integration quality, not resolution generation.

Installation and Wiring Constraints

  • Supply voltage: 10 to 30 VDC
  • Set Profibus address by rotary switches before commissioning
  • Set terminating resistor correctly based on bus position
  • Apply scaling and preset only with defined control logic
  • Keep bus wiring isolated from high-noise industrial paths
  • Verify controller mapping before using full resolution output

Integration logic:

  • A / B = Profibus communication
  • UB / GND = supply
  • Diagnostic supports position or parameter error
  • Factory setting user address = 00

Incorrect scaling, addressing, or parameter mapping will invalidate high-resolution feedback before any mechanical limit is reached.

Replacement and Interface Mapping

  • Suitable for systems requiring high-resolution absolute feedback over Profibus DP
  • Applicable where fine position granularity and multiturn tracking are critical
  • Not suitable where controller scaling or Profibus integration cannot be controlled
  • Designed for networked absolute positioning, not SSI-only systems

Key Data

  • Model: PMG10-SHD.13P0.36000.A
  • Type: Absolute encoder, Profibus DP
  • Shaft: Ø11 mm solid shaft
  • Mounting: EURO flange B10
  • Protection class: D, for dusty abrasive environments
  • Supply voltage: 10 to 30 VDC
  • Interface: Profibus-DPV0
  • Transmission rate: 9.6 to 12000 kBaud
  • Singleturn resolution: 13 bit / 8192 steps
  • Multiturn resolution: 16 bit / 65536 revolutions
  • Initializing time: ≤500 ms
  • Max speed: ≤6000 rpm
  • Admitted shaft load: ≤450 N axial, ≤650 N radial
  • Protection: IP66 / IP67
  • Operating temperature: -40 to +85 °C
  • Connection: Bus connecting box

PMG10-SHD.13P0.30000.A Incremental Encoder
PMG10-SHL.15P0.36000.A Incremental Encoder Solution
PMG10-SHD.1FP0.36000.A High Resolution Encoder
PMG10-SHD.15P0.36000.A Industrial Encoder

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

PMG10-SHD.15P0.36000.A Profibus Encoder Diagnostic Solution

Previous

PMG10-SHD.1FP0.36000.A Profibus Encoder Integration

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
1423
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

OCD-PPA1G-0010-B15S-PAP:Parallel Encoder 1:1 Replacement

OCD-PPA1G-0010-B15S-PAP:Parallel Encoder 1:1 Replacement

EncoderWorks Team
CEV65S-10056: An Alternative Solution for an SSI Protocol Absolute Encoder

CEV65S-10056: An Alternative Solution for an SSI Protocol Absolute Encoder

EncoderWorks Team
OCE-DPC1B-0012-F12W-HFZ Posital Absolute Encoders Profibus-DP (Replacement model)

OCE-DPC1B-0012-F12W-HFZ Posital Absolute Encoders Profibus-DP (Replacement model)

EncoderWorks Team
10-S13Y1_R-50: This is a set of discontinued pull-wire sensors

10-S13Y1_R-50: This is a set of discontinued pull-wire sensors

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com