EncoderWorks EncoderWorks
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About
Home › Selection & Replacement › PSS58N-F1AAGR0BN-0013 PROFIBUS 13-Bit Shaft Boundary

PSS58N-F1AAGR0BN-0013 PROFIBUS 13-Bit Shaft Boundary

EncoderWorks Team
2 yearsago

EncoderWorks can configure PSS58N-F1AAGR0BN-0013 as a custom compatible replacement solution where the PROFIBUS 13-bit singleturn scaling, terminal wiring, and Ø10 mm recessed hollow-shaft boundary must remain aligned. The failure boundary is defined by 8192 steps per revolution, address setting, bus termination, Bus In / Bus Out continuity, preset behavior, rotation direction, shaft concentricity, and torque-rest loading. Typical production lead time: 15 working days.

This model is used as a singleturn absolute rotary encoder in PROFIBUS position systems where one revolution is converted into a defined angular value. A compatible replacement must preserve the installed terminal-side bus path, binary position format, scaling relationship, and anti-rotation method so the machine does not restart with angular offset, communication loss, or shaft-load stress.

PSS58N-F1AAGR0BN-0013 PROFIBUS 13-Bit Shaft Boundary-EncoderWorks
PSS58N-F1AAGR0BN-0013 PROFIBUS 13-Bit Shaft Boundary-EncoderWorks

System Limits

The first system boundary is the 13-bit singleturn scaling and PROFIBUS terminal relationship. PSS58N-F1AAGR0BN-0013 uses binary position data with 8192 angular steps per revolution, so the controller expects the same scaling value, rotation direction, preset behavior, address, device-class configuration, and diagnostic response. If the replacement is configured as a 16-bit unit, uses the wrong parameter length, has a duplicated address, reversed A/B data lines, incorrect termination, or mismatched preset handling, the result can be wrong angular position, proportional angle error, direction reversal, configuration error, communication loss, or data timeout. Terminal-side Bus In and Bus Out continuity are part of the same boundary because the outgoing PROFIBUS segment can be affected by wiring error or termination switch position.

The second boundary is the Ø10 mm recessed hollow-shaft and removable terminal-cover installation. A smaller bore requires careful control of shaft fit, insertion depth, concentricity, torque-rest position, radial cable exit, shield landing, cable strain relief, and cover sealing. Excessive shaft offset, rigid torque-rest preload, poor shield termination, terminal strain, or water and dust exposure at the cover can cause bearing stress, unstable bus exchange, signal dropout, ingress failure, or early mechanical damage even when the electronic configuration is correct.

Wiring & Installation

Before replacement, confirm the full installed model code, PROFIBUS address, terminal assignment, Bus In and Bus Out routing, controller device class, 13-bit singleturn scaling, preset use, rotation direction, diagnostic settings, termination position, and Ø10 mm shaft interface. The “00” position in this singleturn code should not be treated as a multiturn value; the replacement boundary is the angular resolution and terminal-side bus behavior expected by the controller.

During installation, the Ø10 mm recessed hollow shaft should slide onto the machine shaft without forcing the encoder body into alignment. The torque rest should stop housing rotation while avoiding side load on the bearings. Keep PROFIBUS shield continuity through the terminal compartment, route bus wiring away from motor and brake cables, avoid sharp bending at the radial exit, and close the terminal cover so sealing, grounding, and cable strain relief remain stable during machine motion.

Custom Compatible Solution

  • Match the PROFIBUS interface, binary data format, and 13-bit singleturn resolution
  • Preserve address setting, bus termination logic, terminal mapping, Bus In / Bus Out continuity, preset behavior, and rotation direction
  • Adapt the Ø10 mm recessed hollow shaft, radial cable exit, terminal cover, housing envelope, and torque-rest boundary
  • Review shield continuity, terminal sealing, shaft concentricity, IP exposure, and commissioning risk before shipment

Key Data

ItemData
ModelPSS58N-F1AAGR0BN-0013
Device typeSingleturn absolute rotary encoder
InterfacePROFIBUS, RS-485
Data formatBinary
Singleturn resolution13 bit, 8192 steps
Overall resolution13-bit singleturn code combination
Multiturn resolutionNot applicable
Supply voltage10–30 V DC
ConnectionAG, removable housing cover with terminal compartment
Cable exitR, radial
Shaft / boreF1A, recessed hollow shaft, Ø10 mm × 30 mm
Housing materialN, aluminium, powder coated
Option code0, no option
Temperature / expansion codeN, not expanded
Protection classIP65 / IP66 sealing boundary requires confirmation against installed version
Key replacement checksPROFIBUS address, bus termination, terminal mapping, Bus In / Bus Out continuity, 13-bit scaling, preset use, rotation direction, Ø10 mm hollow-shaft fit, torque-rest preload

Related Models

  1. PSS58N-F3AAGR0BN-0013 PROFIBUS Singleturn Absolute Encoder Custom Solution
  2. PSS58N-F2AAZR0BN-0016 PROFIBUS M12 Scaling Boundary
  3. PSS58N-F2AAZR0BN-0013 PROFIBUS 13-Bit Scaling
  4. PSS58N-F2AAZR0BN-0016 PROFIBUS 16-Bit Scaling
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

RSI594 1042801-01/1042801-02: Introduction to Custom Production of Alternative Models

Previous

PSS58N-F3AAGR0BN-0016 PROFIBUS 15 mm Shaft Scaling

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
1423
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

OCD-DPC1B-1212-B14S-H72: Your Custom-Engineered Profibus Absolute Encoder

OCD-DPC1B-1212-B14S-H72: Your Custom-Engineered Profibus Absolute Encoder

EncoderWorks Team
OCD-EEC1B-1216-S06S-PRM:EtherNet Encoder Replacement Solution

OCD-EEC1B-1216-S06S-PRM:EtherNet Encoder Replacement Solution

EncoderWorks Team
Posital Absolute Encoder OCE-EIC1B-1413-W12W-2RW – Replacement Model, Profinet Interface

Posital Absolute Encoder OCE-EIC1B-1413-W12W-2RW – Replacement Model, Profinet Interface

EncoderWorks Team
OCD-PPA1G-0008-SA10-CRW:Parallel Encoder 1:1 Replacement

OCD-PPA1G-0008-SA10-CRW:Parallel Encoder 1:1 Replacement

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com