We have developed a custom solution for model PSS58N-F2AAZR0BN-0013, based on a PROFIBUS singleturn encoder platform with a 12 mm recessed hollow shaft and connector-based wiring structure. This version is suitable for projects that prefer faster connectorized installation while maintaining stable absolute position feedback. Typical production lead time: 15 working days.
Technical Key Parameters
- PROFIBUS interface, RS-485 communication
- Singleturn resolution: 13 bit
- Recessed hollow shaft: Ø12 mm × 30 mm
- Connection type: AZ with M12 connectors
- Supply voltage: 10–30 VDC
Custom Solution Photos


Wiring and Installation Notes
This AZ version is designed for connector-based assembly, but PROFIBUS wiring rules remain unchanged. Signal polarity must stay consistent, shield continuity should be maintained, and the node address must be unique. Termination should only be enabled at the end of the bus segment. The connector system can simplify on-site assembly, but it does not replace correct grounding and bus topology practices. During shaft installation, avoid using cable force or housing rotation to correct alignment.
Custom Compatible Encoder Solution
- 12 mm recessed hollow shaft layout
- M12 connector-based field installation
- 13-bit singleturn absolute output
- Suitable for compact PROFIBUS cabinet integration
Lead Time and Custom Development
This connector-based version can be arranged according to project-side installation and wiring preferences. Typical production lead time: 15 working days.
Technical Parameters Table
| Layer | Item | Specification |
|---|---|---|
| Interface | Communication | PROFIBUS / RS-485 |
| Interface | Connection type | AZ with M12 connectors |
| Resolution | Singleturn | 13 bit |
| Electrical | Supply voltage | 10–30 VDC |
| Mechanical | Shaft type | Recessed hollow shaft |
| Mechanical | Shaft size | Ø12 mm × 30 mm |
| Mechanical | Housing material | Powder-coated aluminum |
| Environmental | Protection class | IP65 |
| Environmental | Operating temperature | -40 … 85 °C |
Technical Summary
This model combines singleturn PROFIBUS feedback with a 12 mm hollow shaft and connectorized installation format, making it suitable for projects that value cleaner field wiring.