ATM90-PTG13x13 PROFIBUS Hollow Shaft Encoder Solution

Mr.Li
9 monthsago

A custom compatible encoder solution can be provided for ATM90-PTG13x13 in maintenance, retrofit, replacement, and upgrade applications. This configuration is typically used in systems relying on PROFIBUS DP communication, multiturn absolute position feedback, and through-hollow shaft mounting with a radial bus adapter connection. Typical production lead time: 15 working days. During engineering review, key matching points include PROFIBUS DPV0 communication behavior, 13 bit × 13 bit resolution structure, 12 mm shaft interface, bus adapter topology, and installation continuity under existing field conditions.

Technical Overview of the ATM90-PTG13x13 Encoder

The ATM90-PTG13x13 is a multiturn absolute encoder built on a through-hollow shaft platform with PROFIBUS DP DPV0 interface. Its coded resolution is 13 bit singleturn combined with 13 bit multiturn, corresponding to 8,192 steps per revolution and 8,192 turns in the ATM90 series table. Within this platform, it represents the highest resolution combination shown for the PROFIBUS DP variants, making it suitable where both fine angular position detail and extended multiturn range are required.

The platform uses magnetic scanning for singleturn detection and a mechanical gearbox for multiturn counting, allowing operation without battery dependency. The series overview also notes shallow installation depth of about 60 mm together with high resistance to shock and vibration. In retrofit work, compatibility should therefore be reviewed not only at the protocol level, but also in terms of multiturn operating principle, maintenance behavior, and mechanical durability under industrial service conditions.

For this coded version, the connection type is a radial bus adapter with three M14, 7-pin interfaces. That configuration directly affects bus wiring layout, service access, and connector-side sealing during replacement work.

Industrial Integration Considerations

The first integration checkpoint is PROFIBUS communication continuity. A compatible solution should match the original PLC or controller setup, including DPV0 communication structure, resolution mapping, and parameter handling. Since the ATM90 series supports programming or parameterization, correct engineering settings remain part of successful commissioning rather than a secondary task.

The second checkpoint is resolution consistency. Because this coded version uses 13 bit × 13 bit structure, controller-side scaling, position processing, and multiturn interpretation should all be preserved during retrofit. A lower-resolution substitute may fit mechanically while still changing the effective feedback behavior seen by the control system.

Environmental continuity also matters. The series overview specifies operating temperature from –20 °C to +80 °C depending on model and IP65 protection, with shaft seal performance influenced by the installed mating connection. In practice, connector condition and assembly quality remain part of the replacement result.

Field Installation and Wiring Notes

For this model, field installation should focus on the radial bus adapter layout. Compared with cable gland versions, the adapter provides an organized fieldbus connection structure, but it also requires sufficient radial space for connector engagement and service access. In compact machinery, limited side clearance can become a practical retrofit issue even where shaft dimensions remain unchanged.

PROFIBUS wiring should preserve bus continuity and shielding integrity. Incoming and outgoing bus paths, node addressing, and segment termination should all be checked before startup. In many field cases, unstable communication is caused by connector reassignment, shielding interruption, or termination errors introduced during maintenance rather than by encoder hardware failure.

Mechanical installation should focus on the 12 mm through-hollow shaft interface. Shaft fit, insertion condition, and alignment should be verified before operation. Because the platform is intended for demanding industrial duty, poor mounting quality can shorten service life or weaken vibration performance even if communication remains normal.

Custom Compatible Encoder Solution

A custom compatible encoder solution for ATM90-PTG13x13 typically focuses on:

  • PROFIBUS DPV0 communication and parameter continuity
  • 13 bit × 13 bit multiturn feedback structure
  • 12 mm through-hollow shaft installation fit
  • Radial bus adapter wiring with bus continuity preservation
  • Stable operation under vibration, shock, and temperature variation

These aspects should be confirmed during engineering review to ensure alignment with the original system configuration.

Custom Solution Photos

ATM90-PTG13x13 PROFIBUS Hollow Shaft Encoder Solution-EncoderWorks
ATM90-PTG13x13 PROFIBUS Hollow Shaft Encoder Solution-EncoderWorks

Lead Time and Custom Development

Typical production lead time: 15 working days.

Custom development usually starts with confirmation of communication settings, coded resolution structure, bus adapter layout, and shaft installation conditions before final release.

Typical Technical Parameters

ParameterSpecification
ModelATM90-PTG13x13
Encoder TypeMultiturn absolute encoder
Shaft TypeThrough-hollow shaft
Shaft Diameter12 mm
InterfacePROFIBUS DP
Interface DetailDPV0
Resolution13 bit × 13 bit
Steps per Revolution8,192
Number of Turns8,192
Connection TypeBus adapter, 3 × M14, 7-pin, radial
ParameterizationProgrammable / parameterizable
Scanning PrincipleMagnetic singleturn scanning
Multiturn PrincipleMechanical gearbox, no battery
Installation DepthApprox. 60 mm
Protection ClassIP65
Operating Temperature–20 °C to +80 °C
Key StrengthsShallow installation depth, high shock resistance, high vibration resistance

Related Models

ATM90-PTG12x12 PROFIBUS Hollow Shaft Encoder
ATM90-PTG13x11 PROFIBUS Hollow Shaft Encoder Solution
ATM90-PTG11x13 Hollow Shaft PROFIBUS Encoder
ATM90-PUG12x12 PROFIBUS Hollow Shaft Encoder
ATM90-PXG12x12 Balanced PROFIBUS Encoder

Industrial Encoder Technical Consultant

Contact

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi365@gmail.com

Industrial Encoder Technical Consultant

Contact

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi365@gmail.com

ATM90-PTG12x12 PROFIBUS Hollow Shaft Encoder Solution

Previous

ATM90-PUG13x13 High-Resolution PROFIBUS Hollow Shaft Encoder Solution

Next

Mr.Li

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi365@gmail.com
1199
Posts
0
Comments
0
Likes

Articles

CEV100M-01169 SSI Multiturn Encoder Engineering Solution (ALT.:100-01169)
BMB 3G.24C8192-C0-A SSI Clamping Flange Encoder Engineering Solution
BMA 3G.24C8192-C6-4 SSI Shaft Encoder Solution
BMA 3G.24C8192-C6-5 SSI Encoder Custom Solution

Related posts

Solve OCE-S101B-1213-E140-HFZ Sourcing Issues | High-Quality Custom Alternative

Solve OCE-S101B-1213-E140-HFZ Sourcing Issues | High-Quality Custom Alternative

Mr.Li
OCE-EIC1B-1416-F12S-CRW Posital Absolute Encoders Profinet (Replacement model)

OCE-EIC1B-1416-F12S-CRW Posital Absolute Encoders Profinet (Replacement model)

Mr.Li
OCD-EEC1B-0016-B06A-PSM:EtherNet Encoder Replacement Solution

OCD-EEC1B-0016-B06A-PSM:EtherNet Encoder Replacement Solution

Mr.Li
OCE-EIC1B-1413-E140-CRW Posital Absolute Encoders Profinet (Replacement model)

OCE-EIC1B-1413-E140-CRW Posital Absolute Encoders Profinet (Replacement model)

Mr.Li

About

EncoderWorks is an engineering-focused platform for industrial encoder technology, protocol compatibility, and application-level technical solutions. We support absolute, incremental, and explosion-proof encoder systems with emphasis on system integration, operational reliability, and motion control performance in demanding industrial environments.

Column

Home About Us Solutions Absolute Encoder Incremental Encoder Draw Wire Sensors Technical Insights Contact

links

Rotary Encoder
Copyright © 2026 EncoderWorks. Designed by Maxlee.
  • Home
  • Solutions
    • SSI
    • RS485 / Modbus-RTU
    • CANopen
    • Analog
    • Profinet
    • Profibus
    • Parallel
    • EtherCAT
    • EtherNET
    • Incremental
  • Absolute Encoder
  • Incremental Encoder
  • Draw Wire Sensors
  • Technical Insights
  • Contact
  • AMG11P29Z0
  • Prescale Film
  • 862229127
  • Absolute Encoder
  • FG4K-1024G-90G-NG
  • PVM78E-011K2R0BN-1213
  • 809645­-01
  • 825860-01
  • 14-1436X-200
  • AVS78E-022K2A0GN-0012

Mr.Li

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi365@gmail.com