A custom compatible encoder solution can be provided for ATM90-PTG13x13 in maintenance, retrofit, replacement, and upgrade applications. This configuration is typically used in systems relying on PROFIBUS DP communication, multiturn absolute position feedback, and through-hollow shaft mounting with a radial bus adapter connection. Typical production lead time: 15 working days. During engineering review, key matching points include PROFIBUS DPV0 communication behavior, 13 bit × 13 bit resolution structure, 12 mm shaft interface, bus adapter topology, and installation continuity under existing field conditions.
Technical Overview of the ATM90-PTG13x13 Encoder
The ATM90-PTG13x13 is a multiturn absolute encoder built on a through-hollow shaft platform with PROFIBUS DP DPV0 interface. Its coded resolution is 13 bit singleturn combined with 13 bit multiturn, corresponding to 8,192 steps per revolution and 8,192 turns in the ATM90 series table. Within this platform, it represents the highest resolution combination shown for the PROFIBUS DP variants, making it suitable where both fine angular position detail and extended multiturn range are required.
The platform uses magnetic scanning for singleturn detection and a mechanical gearbox for multiturn counting, allowing operation without battery dependency. The series overview also notes shallow installation depth of about 60 mm together with high resistance to shock and vibration. In retrofit work, compatibility should therefore be reviewed not only at the protocol level, but also in terms of multiturn operating principle, maintenance behavior, and mechanical durability under industrial service conditions.
For this coded version, the connection type is a radial bus adapter with three M14, 7-pin interfaces. That configuration directly affects bus wiring layout, service access, and connector-side sealing during replacement work.
Industrial Integration Considerations
The first integration checkpoint is PROFIBUS communication continuity. A compatible solution should match the original PLC or controller setup, including DPV0 communication structure, resolution mapping, and parameter handling. Since the ATM90 series supports programming or parameterization, correct engineering settings remain part of successful commissioning rather than a secondary task.
The second checkpoint is resolution consistency. Because this coded version uses 13 bit × 13 bit structure, controller-side scaling, position processing, and multiturn interpretation should all be preserved during retrofit. A lower-resolution substitute may fit mechanically while still changing the effective feedback behavior seen by the control system.
Environmental continuity also matters. The series overview specifies operating temperature from –20 °C to +80 °C depending on model and IP65 protection, with shaft seal performance influenced by the installed mating connection. In practice, connector condition and assembly quality remain part of the replacement result.
Field Installation and Wiring Notes
For this model, field installation should focus on the radial bus adapter layout. Compared with cable gland versions, the adapter provides an organized fieldbus connection structure, but it also requires sufficient radial space for connector engagement and service access. In compact machinery, limited side clearance can become a practical retrofit issue even where shaft dimensions remain unchanged.
PROFIBUS wiring should preserve bus continuity and shielding integrity. Incoming and outgoing bus paths, node addressing, and segment termination should all be checked before startup. In many field cases, unstable communication is caused by connector reassignment, shielding interruption, or termination errors introduced during maintenance rather than by encoder hardware failure.
Mechanical installation should focus on the 12 mm through-hollow shaft interface. Shaft fit, insertion condition, and alignment should be verified before operation. Because the platform is intended for demanding industrial duty, poor mounting quality can shorten service life or weaken vibration performance even if communication remains normal.
Custom Compatible Encoder Solution
A custom compatible encoder solution for ATM90-PTG13x13 typically focuses on:
- PROFIBUS DPV0 communication and parameter continuity
- 13 bit × 13 bit multiturn feedback structure
- 12 mm through-hollow shaft installation fit
- Radial bus adapter wiring with bus continuity preservation
- Stable operation under vibration, shock, and temperature variation
These aspects should be confirmed during engineering review to ensure alignment with the original system configuration.
Custom Solution Photos


Lead Time and Custom Development
Typical production lead time: 15 working days.
Custom development usually starts with confirmation of communication settings, coded resolution structure, bus adapter layout, and shaft installation conditions before final release.
Typical Technical Parameters
| Parameter | Specification |
|---|---|
| Model | ATM90-PTG13x13 |
| Encoder Type | Multiturn absolute encoder |
| Shaft Type | Through-hollow shaft |
| Shaft Diameter | 12 mm |
| Interface | PROFIBUS DP |
| Interface Detail | DPV0 |
| Resolution | 13 bit × 13 bit |
| Steps per Revolution | 8,192 |
| Number of Turns | 8,192 |
| Connection Type | Bus adapter, 3 × M14, 7-pin, radial |
| Parameterization | Programmable / parameterizable |
| Scanning Principle | Magnetic singleturn scanning |
| Multiturn Principle | Mechanical gearbox, no battery |
| Installation Depth | Approx. 60 mm |
| Protection Class | IP65 |
| Operating Temperature | –20 °C to +80 °C |
| Key Strengths | Shallow installation depth, high shock resistance, high vibration resistance |