A custom compatible encoder solution can be provided for ATM90-PTG13x11 in maintenance, retrofit, replacement, and upgrade applications. This configuration is typically used in systems relying on PROFIBUS DP communication, multiturn absolute position feedback, and through-hollow shaft mounting with a radial bus adapter connection. Typical production lead time: 15 working days. During engineering review, key matching points include PROFIBUS DPV0 communication behavior, 13 bit × 11 bit resolution structure, 12 mm shaft interface, bus adapter topology, and installation continuity under existing field conditions.
Technical Overview of the ATM90-PTG13x11 Encoder
The ATM90-PTG13x11 is a multiturn absolute encoder built on a through-hollow shaft platform with PROFIBUS DP DPV0 interface. Its coded resolution is 13 bit singleturn combined with 11 bit multiturn, corresponding to 8,192 steps per revolution and 2,048 turns within the ATM90 series table. This configuration is suitable where higher angular resolution per revolution is required while still preserving multiturn position continuity in the control system.
The platform uses magnetic scanning for singleturn detection and a mechanical gearbox for multiturn counting, allowing operation without battery dependency. The series overview also notes shallow installation depth of about 60 mm and strong resistance to shock and vibration. In retrofit work, that means compatibility should be judged not only by interface naming, but also by multiturn operating principle, maintenance behavior, and mechanical stability in real service conditions.
For this coded version, the connection type is a radial bus adapter rather than a cable gland or M23 plug. That affects both the fieldbus wiring layout and the available service space around the encoder body.
Industrial Integration Considerations
The first integration checkpoint is PROFIBUS communication continuity. A compatible solution should match the original PLC or controller setup, including DPV0 communication structure, resolution mapping, and parameter handling. Since the ATM90 platform supports programming or parameterization, correct engineering settings remain part of successful commissioning rather than a secondary detail.
The second checkpoint is bus topology preservation. The bus adapter version is typically selected where structured bus in / bus out continuity is needed. In retrofit projects, this means node integration, connector assignment, and termination strategy should be reviewed together instead of treating the encoder as an isolated device.
A third point is environmental continuity. The ATM90 series overview specifies operating temperature from –20 °C to +80 °C depending on model and IP65 protection, with shaft seal performance influenced by the installed mating connection. In practice, connector condition, sealing integrity, and assembly quality remain part of the compatibility requirement.
Field Installation and Wiring Notes
For this model, field installation should focus on the radial bus adapter layout. Compared with cable gland versions, the adapter provides a more defined bus connection structure, but it also requires sufficient side clearance for connector handling and service access. In compact machinery, connector interference can become a real retrofit issue even when the shaft dimensions are correct.
PROFIBUS wiring should preserve bus continuity and shielding integrity. Incoming and outgoing bus paths, node addressing, and segment termination should all be checked before startup. In many field cases, unstable communication is caused by connector reassignment, poor shielding continuity, or termination errors introduced during maintenance rather than by encoder failure.
Mechanical installation should focus on the 12 mm through-hollow shaft interface. Shaft fit, insertion condition, and alignment should be verified before operation. Because the platform is intended for demanding industrial duty, poor mounting quality can shorten service life or weaken vibration performance even if communication remains normal.
Custom Compatible Encoder Solution
A custom compatible encoder solution for ATM90-PTG13x11 typically focuses on:
- PROFIBUS DPV0 communication and parameter continuity
- 13 bit × 11 bit multiturn feedback structure
- 12 mm through-hollow shaft installation fit
- Radial bus adapter wiring with bus continuity preservation
- Stable operation under vibration, shock, and temperature variation
These aspects should be confirmed during engineering review to ensure alignment with the original system configuration.
Custom Solution Photos


Lead Time and Custom Development
Typical production lead time: 15 working days.
Custom development usually starts with confirmation of communication settings, coded resolution structure, bus adapter layout, and shaft installation conditions before final release.
Typical Technical Parameters
| Parameter | Specification |
|---|---|
| Model | ATM90-PTG13x11 |
| Encoder Type | Multiturn absolute encoder |
| Shaft Type | Through-hollow shaft |
| Shaft Diameter | 12 mm |
| Interface | PROFIBUS DP |
| Interface Detail | DPV0 |
| Resolution | 13 bit × 11 bit |
| Steps per Revolution | 8,192 |
| Number of Turns | 2,048 |
| Connection Type | Bus adapter, 3 × M14, 7-pin, radial |
| Parameterization | Programmable / parameterizable |
| Scanning Principle | Magnetic singleturn scanning |
| Multiturn Principle | Mechanical gearbox, no battery |
| Installation Depth | Approx. 60 mm |
| Protection Class | IP65 |
| Operating Temperature | –20 °C to +80 °C |
| Key Strengths | Shallow installation depth, high shock resistance, high vibration resistance |