A custom compatible encoder solution can be provided for ATM90-PUG13x11 in maintenance, retrofit, replacement, and upgrade applications. This configuration is typically used in systems relying on PROFIBUS DP communication, multiturn absolute position feedback, and through-hollow shaft installation with cable gland wiring. Typical production lead time: 15 working days. During engineering review, key matching points include PROFIBUS communication behavior, 13 bit × 11 bit resolution structure, shaft fit, cable entry method, and sealing continuity under existing field conditions.
Technical Overview of the ATM90-PUG13x11 Encoder
The ATM90-PUG13x11 is a multiturn absolute encoder using a through-hollow shaft structure and PROFIBUS DP interface (DPV0). The resolution configuration is 13 bit singleturn combined with 11 bit multiturn, corresponding to high per-revolution precision with extended turn tracking capability.
This platform uses magnetic scanning for singleturn detection and a mechanical gearbox for multiturn counting without battery dependency. It is designed for long-term operation with reduced maintenance requirements. The mechanical structure features shallow installation depth and robust construction suitable for applications with mechanical load and vibration.
The specific coded version uses a 1/2″ hollow shaft and cable gland connection, which defines both installation geometry and field wiring constraints.
Industrial Integration Considerations
The primary integration requirement is PROFIBUS communication continuity. A compatible solution should match the original PLC configuration, including DPV0 communication structure, resolution mapping, and parameterization behavior. Since this platform supports programmable settings, incorrect parameter alignment may affect commissioning even when hardware appears compatible.
The second consideration is resolution and multiturn structure matching. The 13 bit × 11 bit configuration must align with the original system’s scaling and position interpretation. Any deviation can impact controller calculations and motion logic.
Environmental and mechanical conditions should also be considered. The platform is designed for demanding industrial use with defined temperature range and sealing concept. Shaft engagement, installation space, and enclosure integrity should be preserved during replacement.
Field Installation and Wiring Notes
For this model, cable gland wiring is a key installation factor. Compared with connector-based versions, gland entry requires careful handling of cable routing, bending radius, and sealing during installation. The replacement solution should maintain the original cable exit direction and enclosure protection.
PROFIBUS wiring should preserve bus continuity and shielding integrity. Cable shielding should be properly grounded, and routing should avoid interference from power lines. Communication issues in field applications are often caused by wiring or grounding changes rather than encoder hardware.
Mechanical installation should focus on the hollow shaft fit. Shaft diameter, insertion depth, and alignment must be verified before operation. Improper fit or misalignment may introduce mechanical stress and reduce service life, especially in applications with vibration or dynamic loading.
Custom Compatible Encoder Solution
A custom compatible encoder solution for ATM90-PUG13x11 typically focuses on:
- PROFIBUS DP communication and parameterization continuity
- 13 bit × 11 bit multiturn feedback structure
- 1/2″ through-hollow shaft mechanical fit
- Cable gland wiring, shielding, and sealing consistency
- Installation stability under vibration and temperature variation
These aspects should be confirmed during engineering review to ensure compatibility with the original system.
Custom Solution Photos


Lead Time and Custom Development
Typical production lead time: 15 working days.
Custom development typically begins with confirmation of communication settings, resolution structure, shaft size, and cable installation requirements.
Typical Technical Parameters
| Parameter | Specification |
|---|---|
| Model | ATM90-PUG13x11 |
| Encoder Type | Multiturn absolute encoder |
| Shaft Type | Through-hollow shaft |
| Shaft Diameter | 1/2″ |
| Interface | PROFIBUS DP (DPV0) |
| Resolution | 13 bit × 11 bit |
| Steps per Revolution | 8,192 |
| Number of Turns | 2,048 |
| Connection Type | Cable gland |
| Parameterization | Programmable |
| Scanning Principle | Magnetic |
| Multiturn Principle | Mechanical gearbox, no battery |
| Installation Depth | Approx. 60 mm |
| Protection Class | IP65 |
| Operating Temperature | –20 °C to +80 °C |
Related Models