EncoderWorks EncoderWorks
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About
Home › Selection & Replacement › FSM58I-F2AK2R3GN-1213 Inox Gray Mapping and Ø12 Shaft Fit

FSM58I-F2AK2R3GN-1213 Inox Gray Mapping and Ø12 Shaft Fit

EncoderWorks Team
2 monthsago

When replacing FSM58I-F2AK2R3GN-1213, the EncoderWorks custom compatible replacement should first control Inox housing requirements, radial Gray-code cable mapping, and Ø12 mm recessed hollow-shaft fit. This model should not be treated as only a radial-exit variant. The real risk is that the 25-bit Gray word may be active, while the controller reads a different position because cable mapping, LATCH state, V/R logic, or PRESET wiring has changed.

The FSM58I-F2AK2R3GN-1213 is a multiturn absolute encoder with fast parallel push-pull output, Inox stainless-steel housing, F2A Ø12 mm recessed hollow shaft, K2 cable output, radial exit direction, Gray code, and V/R, LATCH, PRESET inputs. FSM58 uses direct high-speed position data transfer, 25-bit multiturn output, short-circuit-protected push-pull outputs, and code change frequency up to 400 kHz.

FSM58I-F2AK2R3GN-1213 Inox Gray Mapping and Ø12 Shaft Fit-EncoderWorks
FSM58I-F2AK2R3GN-1213 Inox Gray Mapping and Ø12 Shaft Fit-EncoderWorks

The first failure boundary is Gray cable mapping. Data bit 1 through Data bit 25, Ub, GND, V/R, LATCH, and PRESET must be verified by signal function, not by conductor color. A cable-output encoder is vulnerable to old junction-box changes, cabinet rewiring, or field cable extensions. One shifted Gray bit can create a stable but wrong absolute position.

This replacement fails when all 25 Gray outputs are switching, but the PLC decodes the wrong shaft position because cable mapping, bit order, or LATCH wiring does not match the original machine. The encoder looks alive, but the cabinet is reading a different absolute word.

The second boundary is input-state control. LATCH freezes the parallel position word for stable reading. V/R changes counting direction. PRESET sets the electrical zero. These inputs are separate from the data outputs and must not be treated as spare conductors during replacement.

The Inox housing helps in wet, corrosive, washdown, or exposed areas, but it does not correct cable strain or torque-rest preload. The radial cable exit needs enough clearance, and the Ø12 mm recessed hollow shaft should mount without force. The torque rest should only prevent housing rotation, not pull the encoder into alignment.

The replacement decision should first confirm Inox housing requirement, F2A Ø12 mm shaft fit, torque-rest freedom, radial cable routing, 25-bit Gray data order, V/R direction logic, LATCH timing, PRESET behavior, supply voltage, shielding, and controller input thresholds. EncoderWorks treats FSM58I-F2AK2R3GN-1213 as an industrial encoder custom compatible solution where Gray cable mapping and radial-exit mechanics decide field reliability.

Typical production lead time: 15 working days.

Key Data

ItemData
ModelFSM58I-F2AK2R3GN-1213
Encoder typeMultiturn absolute encoder
InterfaceFast parallel push-pull
HousingØ58 mm Inox stainless-steel housing
Shaft typeRecessed hollow shaft
Shaft sizeF2A, Ø12 mm x 30 mm
ConnectionK2 cable output
Exit directionRadial
Output codeGray code
Resolution13-bit singleturn + 12-bit multiturn / 25 bit total
Operating voltage10–30 VDC
Code change frequencyUp to 400 kHz
InputsV/R, LATCH, PRESET
Main engineering anchorInox Gray mapping and Ø12 shaft fit
Main failure boundaryWrong Gray mapping, LATCH error, PRESET fault, radial cable strain
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

FSM58I-F3AK2A3BN-1213 Inox Binary Output and Ø15 Shaft Fit

Previous

FVS58N-011K2R3GN-0013 Gray Cable Mapping and Clamping Flange

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
1423
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

OCM-EIC1B-0013-F10W-ARW Posital Absolute Encoders Profinet (Replacement model)

OCM-EIC1B-0013-F10W-ARW Posital Absolute Encoders Profinet (Replacement model)

EncoderWorks Team
OCE-EIC1B-0013-F12S-2RW Posital Absolute Encoders Profinet (Replacement model)

OCE-EIC1B-0013-F12S-2RW Posital Absolute Encoders Profinet (Replacement model)

EncoderWorks Team
OCD-PPA1G-0016-B140-CAW Parallel Push-Pull Multiturn Absolute Encoder Custom Solution

OCD-PPA1G-0016-B140-CAW Parallel Push-Pull Multiturn Absolute Encoder Custom Solution

EncoderWorks Team
OCD-DPC1B-1213-S12V-H3P Profibus Absolute Encoder: The Made-to-Order Replacement Choice

OCD-DPC1B-1213-S12V-H3P Profibus Absolute Encoder: The Made-to-Order Replacement Choice

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com