Home › Absolute Encoder › OCD-PPA1B-0010-B12S-CAW Parallel Single-Turn Encoder, 12 mm Hollow Shaft

OCD-PPA1B-0010-B12S-CAW Parallel Single-Turn Encoder, 12 mm Hollow Shaft

EncoderWorks Team
5 monthsago

We developed a custom solution for model OCD-PPA1B-0010-B12S-CAW. Selected when single-turn absolute feedback is required via parallel push-pull output, using a 58 mm blind hollow structure with 12 mm shaft, without adding multi-turn functionality or fieldbus communication. Typical production lead time: 15 working days. The referenced configuration is an optical single-turn version with 10-bit resolution, binary code, 10–30 VDC supply, and IP66/IP67 protection on both shaft side and housing.

Key Specifications

  • Interface: parallel push-pull
  • Resolution: 10-bit single-turn
  • Code: Binary
  • Supply: 10–30 VDC
  • Protection: IP66/IP67
  • Structure: 58 mm blind hollow, 12 mm shaft, 30 mm depth
  • Cable: 1 m axial PVC
  • Speed: up to 3000 rpm

Decision Snapshot

  • Best for: single-turn parallel absolute positioning systems using hollow-shaft installation
  • Key fit: 12 mm hollow shaft, 58 mm blind hollow flange, 30 mm insertion depth
  • Avoid if: the application needs multi-turn retention or bus communication; that follows from the listed single-turn output structure and direct bit mapping.

Custom Solution Photos

OCD-PPA1B-0010-B12S-CAW Parallel Single-Turn Encoder, 12 mm Hollow Shaft-EncoderWorks
OCD-PPA1B-0010-B12S-CAW Parallel Single-Turn Encoder, 12 mm Hollow Shaft-EncoderWorks

Encoder structure reference: 58 mm blind hollow flange, 12 mm shaft, axial 1 m cable outlet.

Signal & Output Logic

  • Bit 1–10 parallel output
  • Includes Latch and DIR control
  • Direction configurable via cable or connector setting

Primary integration reason: direct controller-side reading of single-turn absolute position without protocol conversion. Primary limitation: this structure is efficient for basic parallel absolute systems, but it does not provide multi-turn data or network communication capability. That conclusion follows from the published 10-bit output map and push-pull interface.

Wiring & Installation

  • Connection: 1 m axial PVC cable
  • Cable: AWG 26, 9.3 mm diameter
  • Minimum bend radius: 150 mm

Primary commissioning risk: incorrect controller-side signal mapping on bit order, Latch, and DIR logic. Primary mechanical constraint: blind hollow installation quality. In practice, shaft diameter alone is not enough; insertion depth and alignment quality still matter because the published static and dynamic misalignment limits are tight.

Integration & Compatibility

  • Designed for single-turn parallel absolute encoder systems
  • Matches 58 mm blind hollow installations with 12 mm shaft
  • Suitable for direct position reading without bus conversion
  • Not suitable for multi-turn systems or fieldbus architectures; this is a selection conclusion based on the listed interface and output type.

Lead Time

Typical production lead time: 15 working days. Custom adaptation can be developed around shaft fit, cable length, output assignment, and installation requirements.

Key Technical Data

ItemData
ModelOCD-PPA1B-0010-B12S-CAW
InterfaceParallel push-pull
TypeAbsolute single-turn
SensingOptical
Resolution10 bit
CodeBinary
Supply10–30 VDC
ProtectionIP66/IP67
Flange58 mm blind hollow
Shaft12 mm
Depth30 mm
Cable1 m axial
Speed3000 rpm
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

OCD-PPA1B-00AA-B12S-CAW:Parallel Encoder Replacement Solution

Previous

OCD-PPA1B-0012-B12S-CAW:Parallel Encoder Replacement Solution

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
4345
Posts
0
Comments
0
Likes

Articles

CEV65M-03316 5 m Pin-25 DataBus Disable
CEV65S-10089 7 m SUB-D Gray-Code Capture
CEV65S-50004 SUB-D 25-Pin Gray Bit Mapping
CEV65S-10009 Profibus 360-Step Singleturn

Related posts

OCE-DPC1B-1413-E14W-HFZ Posital Absolute Encoders Profibus-DP (Replacement model)

OCE-DPC1B-1413-E14W-HFZ Posital Absolute Encoders Profibus-DP (Replacement model)

EncoderWorks Team
OCF-DPC1B-0016-S10V-H3E: A Tailored Profibus Absolute Encoder Solution

OCF-DPC1B-0016-S10V-H3E: A Tailored Profibus Absolute Encoder Solution

EncoderWorks Team
OCD-DPC1B-1212-B14S-H3P: Personalize Your Profibus System with This Encoder

OCD-DPC1B-1212-B14S-H3P: Personalize Your Profibus System with This Encoder

EncoderWorks Team
OCD-DPC1B-0012-B140-H72: The Direct-Fit, Custom Solution for Profibus Systems

OCD-DPC1B-0012-B140-H72: The Direct-Fit, Custom Solution for Profibus Systems

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Absolute Encoder Incremental Encoder Draw Wire Sensors Technical Insights Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Solutions
    • SSI
    • RS485 / Modbus-RTU
    • CANopen
    • Analog
    • Profinet
    • Profibus
    • Parallel
    • EtherCAT
    • EtherNET
    • Incremental
  • Absolute Encoder
  • Incremental Encoder
  • Draw Wire Sensors
  • Technical Insights
  • Contact

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com