OCD-PPA1G-0016-C10S-CAW Parallel Single-Turn Encoder, 10 mm Solid Shaft

EncoderWorks Team
6 monthsago

We developed a custom solution for model OCD-PPA1G-0016-C10S-CAW. Selected when high-resolution single-turn absolute feedback is required via parallel push-pull output, using a 58 mm clamping flange and 10 mm solid shaft, without introducing fieldbus communication. Typical production lead time: 15 working days. The referenced configuration is a single-turn absolute version with optical sensing, 16-bit resolution, Gray code, and direct parallel push-pull output.

Key Specifications

  • Interface: parallel push-pull
  • Resolution: 16-bit single-turn
  • Code: Gray
  • Supply: 10–30 VDC
  • Protection: IP66/IP67
  • Structure: 58 mm clamping flange, 10 mm solid shaft, 20 mm shaft length
  • Cable: 1 m axial PVC
  • Speed: up to 3000 rpm

Decision Snapshot

  • Best for: high-resolution single-turn parallel absolute positioning systems
  • Key fit: 10 mm solid shaft, 58 mm clamping flange, 1 m axial cable
  • Avoid if: the application requires multi-turn retention or bus communication; that is an engineering fit judgment based on the listed single-turn parallel output structure.

Custom Solution Photos

OCD-PPA1G-0016-C10S-CAW Parallel Single-Turn Encoder, 10 mm Solid Shaft-EncoderWorks
OCD-PPA1G-0016-C10S-CAW Parallel Single-Turn Encoder, 10 mm Solid Shaft-EncoderWorks

Encoder structure reference: 58 mm clamping flange, 10 mm solid shaft, axial 1 m cable outlet.

Signal & Output Logic

  • Bit 1–16 parallel output
  • Includes Latch and DIR control
  • Direction configurable via cable or connector setting

Primary integration reason: direct controller-side reading of high-resolution single-turn absolute position. Primary limitation: this structure is efficient for parallel control systems, but not suitable for multi-turn applications or networked motion-bus architectures. That conclusion follows from the published 16-bit single-turn output map and push-pull interface.

Wiring & Installation

  • Connection: 1 m axial PVC cable
  • Cable: AWG 26, 9.3 mm diameter
  • Minimum bend radius: 150 mm

Primary commissioning risk: controller-side signal mapping errors on bit order, Latch, and DIR logic. Primary installation constraint: axial cable routing space. The 10 mm shaft should be aligned carefully because the published bearing life varies with axial and radial load.

Integration & Compatibility

  • Designed for single-turn parallel absolute encoder systems
  • Matches 58 mm clamping flange installations with 10 mm solid shaft
  • Suitable for direct high-resolution position reading without bus conversion
  • Not suitable for multi-turn systems or bus architectures; this is a selection conclusion based on the listed interface and output type.

Lead Time

Typical production lead time: 15 working days. Custom adaptation can be developed around shaft fit, cable length, output assignment, and installation requirements.

Key Technical Data

ItemData
ModelOCD-PPA1G-0016-C10S-CAW
InterfaceParallel push-pull
TypeAbsolute single-turn
SensingOptical
Resolution16 bit
CodeGray
Supply10–30 VDC
ProtectionIP66/IP67
Flange58 mm clamping flange
Shaft10 mm solid
Shaft length20 mm
Cable1 m axial
Speed3000 rpm
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

OCD-PPA1G-0710-S100-PRT:Parallel Encoder Replacement Solution

Previous

OCD-PPA1G-0016-C100-CAW:Parallel Encoder Replacement Solution

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
4345
Posts
0
Comments
0
Likes

Articles

CEV65M-03316 5 m Pin-25 DataBus Disable
CEV65S-10089 7 m SUB-D Gray-Code Capture
CEV65S-50004 SUB-D 25-Pin Gray Bit Mapping
CEV65S-10009 Profibus 360-Step Singleturn

Related posts

UCD-DPC1B-0016-H8Y0-H3P: Your Custom-Configured Profibus Encoder Solution

UCD-DPC1B-0016-H8Y0-H3P: Your Custom-Configured Profibus Encoder Solution

EncoderWorks Team
CBE58-8192GKE01 OEM Encoder

CBE58-8192GKE01 OEM Encoder

EncoderWorks Team
CRF58-4096G4096E08 – Custom Replacement

CRF58-4096G4096E08 – Custom Replacement

EncoderWorks Team
CAMX_12//PC5G//11//T3A030 CAMX12-11BT-002 – 1:1 Replacement

CAMX_12//PC5G//11//T3A030 CAMX12-11BT-002 – 1:1 Replacement

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Absolute Encoder Incremental Encoder Draw Wire Sensors Technical Insights Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Solutions
    • SSI
    • RS485 / Modbus-RTU
    • CANopen
    • Analog
    • Profinet
    • Profibus
    • Parallel
    • EtherCAT
    • EtherNET
    • Incremental
  • Absolute Encoder
  • Incremental Encoder
  • Draw Wire Sensors
  • Technical Insights
  • Contact

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com