OCD-PPA1G-1212-B100-CRW Parallel Multi-Turn Encoder, 10 mm Hollow Shaft

EncoderWorks Team
6 monthsago

We developed a custom solution for model OCD-PPA1G-1212-B100-CRW. Selected when multi-turn absolute feedback is required via parallel push-pull output, using a 58 mm blind hollow structure with 10 mm shaft, without changing an existing parallel-control architecture. Typical production lead time: 15 working days. The referenced configuration is an optical multi-turn version with 12-bit single-turn resolution, 12-bit multi-turn resolution, Gray code, a mechanical gear-based multi-turn system without battery, 10–30 VDC supply, and IP65 protection.

Key Specifications

  • Interface: parallel push-pull
  • Resolution: 12-bit single-turn + 12-bit multi-turn
  • Code: Gray
  • Multi-turn: mechanical gear train, no battery
  • Supply: 10–30 VDC
  • Protection: IP65 shaft side, IP65 housing
  • Structure: 58 mm blind hollow, 10 mm shaft, 30 mm depth
  • Cable: 1 m radial PVC
  • Speed: up to 12000 rpm

Decision Snapshot

  • Best for: parallel absolute retrofit systems needing higher-resolution multi-turn position retention
  • Key fit: 10 mm hollow shaft, 58 mm blind hollow flange, 30 mm insertion depth
  • Avoid if: the system is based on fieldbus communication or only requires incremental feedback; that conclusion follows from the listed parallel interface and direct bit-output structure.

Custom Solution Photos

OCD-PPA1G-1212-B100-CRW Parallel Multi-Turn Encoder, 10 mm Hollow Shaft-EncoderWorks
OCD-PPA1G-1212-B100-CRW Parallel Multi-Turn Encoder, 10 mm Hollow Shaft-EncoderWorks

Encoder structure reference: 58 mm blind hollow flange, 10 mm shaft, 1 m radial cable outlet.

Signal & Output Logic

  • Bit 1–24 parallel output
  • Includes Latch and DIR control
  • Direction configurable via cable or connector setting

Primary integration reason: the controller reads direct multi-turn absolute bit data rather than bus telegrams. Primary limitation: this architecture is efficient for parallel retrofit, but it is not suitable for Profibus, CANopen, EtherCAT, or incremental-only systems. That conclusion follows from the published 24-bit output map and push-pull interface.

Wiring & Installation

  • Connection: 1 m radial PVC cable
  • Cable: AWG 26, 7.1 mm diameter
  • Minimum bend radius: 46 mm fixed, 61 mm flexing

Primary commissioning risk: incorrect controller-side bit mapping on high-bit parallel systems. Primary installation value: the listed 12000 rpm maximum speed makes this version suitable where shaft speed matters more than bus integration. Primary mechanical constraint: blind hollow installation quality. The page also lists static and dynamic misalignment limits, so shaft tolerance, insertion depth, and alignment stability should be controlled together, not bore size alone.

Integration & Compatibility

  • Designed for parallel absolute encoder systems
  • Matches 58 mm blind hollow installations with 10 mm shaft
  • Suitable for multi-turn position feedback without battery replacement
  • Not suitable for bus-based control structures or simple incremental feedback use cases; this is a selection conclusion based on the listed interface and output type.

Lead Time

Typical production lead time: 15 working days. Custom adaptation can be developed around shaft fit, cable routing, signal assignment, and installation requirements.

Key Technical Data

ItemData
ModelOCD-PPA1G-1212-B100-CRW
InterfaceParallel push-pull
TypeAbsolute multi-turn
SensingOptical
Resolution12 bit + 12 bit
CodeGray
Multi-turnMechanical gear train
Supply10–30 VDC
ProtectionIP65
Flange58 mm blind hollow
Shaft10 mm
Depth30 mm
Cable1 m radial
Speed12000 rpm
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

OCD-PPA1G-0810-B12S-CRW:Parallel Encoder Replacement Solution

Previous

OCD-PPA1G-0810-B100-CRW:Parallel Encoder Replacement Solution

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
4345
Posts
0
Comments
0
Likes

Articles

CEV65M-03316 5 m Pin-25 DataBus Disable
CEV65S-10089 7 m SUB-D Gray-Code Capture
CEV65S-50004 SUB-D 25-Pin Gray Bit Mapping
CEV65S-10009 Profibus 360-Step Singleturn

Related posts

UCD-DPC1B-1213-HRS0-H72| A Tailored Replacement for Profibus Absolute Encoders

UCD-DPC1B-1213-HRS0-H72| A Tailored Replacement for Profibus Absolute Encoders

EncoderWorks Team
OCD-EEC1B-1416-C10A-PSM:EtherNet Encoder Replacement Solution

OCD-EEC1B-1416-C10A-PSM:EtherNet Encoder Replacement Solution

EncoderWorks Team
OCF-DPC1B-1216-SB90-H3E: Tailored Absolute Encoder Replacement

OCF-DPC1B-1216-SB90-H3E: Tailored Absolute Encoder Replacement

EncoderWorks Team
OCD-PPA1G-0010-S06S-PAP:Parallel Encoder 1:1 Replacement

OCD-PPA1G-0010-S06S-PAP:Parallel Encoder 1:1 Replacement

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Absolute Encoder Incremental Encoder Draw Wire Sensors Technical Insights Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Solutions
    • SSI
    • RS485 / Modbus-RTU
    • CANopen
    • Analog
    • Profinet
    • Profibus
    • Parallel
    • EtherCAT
    • EtherNET
    • Incremental
  • Absolute Encoder
  • Incremental Encoder
  • Draw Wire Sensors
  • Technical Insights
  • Contact

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com