We developed a custom solution for model UCE-AV002-0013-E14S-HFZ. Selected when single-turn absolute position feedback is required as a 0–10 V analog voltage signal in Zone 1 & 21 oil and gas environments, using a 78 mm ATEX blind hollow structure with 14 mm shaft. Typical production lead time: 15 working days. The referenced configuration is a magnetic single-turn version with 13-bit resolution, 8–32 VDC supply, 0–10 V analog output, and CE + ATEX Zone 1 & 21 approval.
Key Specifications
- Interface: analog voltage, 0–10 V
- Resolution: 13-bit single-turn
- Sensing: magnetic
- Supply: 8–32 VDC
- Minimum load resistance: 5 kΩ
- Protection: IP66/IP67
- Structure: 78 mm ATEX blind hollow, 14 mm shaft, 30 mm depth
- Speed: up to 3000 rpm
- Approval: CE + ATEX Zone 1 & 21 (Oil+Gas)
Decision Snapshot
- Best for: hazardous-area analog position feedback in oil and gas systems
- Key fit: 14 mm hollow shaft, 78 mm ATEX blind hollow flange, 0–10 V output
- Avoid if: the project requires multi-turn retention, digital bus communication, or encoder-side network diagnostics; that follows from the listed single-turn analog output structure.
Custom Solution Photos


Encoder structure reference: 78 mm ATEX blind hollow flange, 14 mm shaft, radial sealed terminal layout.
Signal & Output Logic
- Output: analog voltage 0–10 V
- Terminals: Power Supply, GND, Analog Output
- Set functions: Set1/Direction, Set2/Zero Set
- Measuring range: minimum 0–11.25°
Primary integration reason: direct analog position feedback for control systems that do not require bus communication. Primary limitation: this is a single-turn analog encoder, so it is not suitable for multi-turn applications or digital network architectures. The page also notes 32 ms settling time and ±10 mV analog accuracy at 10 V under nominal supply, which makes signal conditioning and receiving-device impedance part of the selection logic.
Wiring & Installation
- Connection: radial, 2 sealed outlets
- Signals: Power Supply, GND, Analog Output, Set1/Direction, Set2/Zero Set
- Startup time: < 500 ms
Primary commissioning risk: analog scaling or zero-setting errors rather than sensing failure. Primary mechanical constraint: blind hollow alignment quality in a hazardous-area installation. Best practice: control shaft tolerance, insertion depth, and receiving-side scaling together, because the encoder output is only as useful as the controller’s analog interpretation.
Integration & Compatibility
- Designed for analog voltage position feedback in Zone 1 & 21 oil and gas environments
- Matches 78 mm ATEX blind hollow installations with 14 mm shaft
- Suitable for direct 0–10 V single-turn position output
- Not suitable for multi-turn systems, pulse-only applications, or Ethernet / fieldbus architectures; this is a selection conclusion based on the listed interface, approval, and output structure.
Lead Time
Typical production lead time: 15 working days. Custom adaptation can be developed around shaft fit, analog scaling range, cable entry, and hazardous-area installation requirements.
Key Technical Data
| Item | Data |
|---|---|
| Model | UCE-AV002-0013-E14S-HFZ |
| Interface | Analog voltage 0–10 V |
| Type | Absolute single-turn |
| Sensing | Magnetic |
| Resolution | 13 bit |
| Supply | 8–32 VDC |
| Output accuracy | ±10 mV @ 10 V |
| Protection | IP66/IP67 |
| Approval | CE + ATEX Zone 1 & 21 |
| Flange | 78 mm ATEX blind hollow |
| Shaft | 14 mm |
| Depth | 30 mm |
| Speed | 3000 rpm |