We developed a custom solution for the OCE-DPC1B-1213-E14W-HFZ model, intended for applications that require Profibus communication together with hazardous-area mechanical protection. This configuration is built around a blind hollow bore structure, a 78 mm ATEX mounting form, and a 14 mm shaft interface, while maintaining 13-bit singleturn and 12-bit multiturn absolute feedback. It is suitable for installations where explosion protection, corrosion resistance, and stable fieldbus integration must be addressed together. Typical production lead time: 15 working days. The original configuration uses a Profibus interface, optical sensing, binary code output, 10–30 VDC supply, and CE + ATEX Zone 1 & 21 approval.

Technical Key Parameters

  • Profibus DP interface with DPV0, DPV1 and DPV2 Class 2 support
  • 13-bit singleturn + 12-bit multiturn resolution
  • Blind hollow bore, 30 mm depth
  • 14 mm bore diameter
  • 78 mm ATEX flange structure
  • 10–30 VDC power supply
  • IP66/IP67 enclosure protection
  • Stainless steel housing and flange
  • Max mechanical speed 3000 rpm
  • CE + ATEX Zone 1 & 21 approval

Custom Solution Photos

OCE-DPC1B-1213-E14W-HFZ Profibus Absolute Encoder Custom Solution-EncoderWorks
OCE-DPC1B-1213-E14W-HFZ Profibus Absolute Encoder Custom Solution-EncoderWorks

Wiring and Installation Notes

For this model, the most important point is not only fieldbus wiring accuracy, but also enclosure integrity in hazardous installations. The Profibus bus-in and bus-out lines, power supply, and grounding path must be kept clear and stable, with shield continuity maintained through the full cable route. Because the unit uses a blind hollow bore design, shaft insertion depth and clamping stability should be checked before commissioning. In ATEX environments, installers should also avoid improvised cable entry changes that could weaken sealing or certification-related protection. The stainless-steel body and flange structure make this layout more suitable for corrosive or exposed industrial areas than a standard painted housing.

Custom Compatible Encoder Solution

  • Custom mechanical solution for 78 mm hazardous-area blind hollow bore mounting
  • Profibus communication adaptation with matching power and bus line arrangement
  • Bore and shaft-fit customization around the 14 mm hollow shaft requirement
  • Reinforced enclosure-oriented design for oil, gas, and other harsh-duty environments

Lead Time and Custom Development

Typical production lead time is 15 working days. For projects involving hazardous-area replacement, we can support mechanical adaptation, fieldbus matching, and enclosure-oriented custom development based on the installation drawing and wiring requirements.

Key Technical Data

ItemData
InterfaceProfibus
Resolution13-bit singleturn / 12-bit multiturn
CodeBinary
Sensing technologyOptical
Supply voltage10–30 VDC
MountingBlind hollow bore, 78 mm ATEX
Bore diameter14 mm
Protection classIP66/IP67
Housing materialStainless steel
ApprovalCE + ATEX Zone 1 & 21
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

OCE-DPC1B-1416-E14W-HFZ Posital Absolute Encoders Profibus-DP (Replacement model)

Previous

OCE-DPC1B-1216-E14W-HFZ Posital Absolute Encoders Profibus-DP (Replacement model)

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
4345
Posts
0
Comments
0
Likes

Articles

CEV65M-03316 5 m Pin-25 DataBus Disable
CEV65S-10089 7 m SUB-D Gray-Code Capture
CEV65S-50004 SUB-D 25-Pin Gray Bit Mapping
CEV65S-10009 Profibus 360-Step Singleturn

Related posts

CEH802M-00009 ODM Replacement Encoder

CEH802M-00009 ODM Replacement Encoder

EncoderWorks Team
Replacement Solution for OCE-CAA1B-1212-F100-HFE | Tailored Fit, Superior Performance

Replacement Solution for OCE-CAA1B-1212-F100-HFE | Tailored Fit, Superior Performance

EncoderWorks Team
OCD-EEC1B-0016-C10S-PCM:EtherNet Encoder Replacement Solution

OCD-EEC1B-0016-C10S-PCM:EtherNet Encoder Replacement Solution

EncoderWorks Team
UCD-DPC1B-1212-H8TS-H3P Profibus Encoder - Engineered as a Direct Replacement

UCD-DPC1B-1212-H8TS-H3P Profibus Encoder - Engineered as a Direct Replacement

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Absolute Encoder Incremental Encoder Draw Wire Sensors Technical Insights Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Solutions
    • SSI
    • RS485 / Modbus-RTU
    • CANopen
    • Analog
    • Profinet
    • Profibus
    • Parallel
    • EtherCAT
    • EtherNET
    • Incremental
  • Absolute Encoder
  • Incremental Encoder
  • Draw Wire Sensors
  • Technical Insights
  • Contact

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com