For PVM58N-YY1AGR0BN-1213, EncoderWorks can provide a custom compatible replacement focused on 25-bit PROFIBUS scaling, Ø10h8 clamping-flange shaft fit, and RS-485 bus setup. This model should not be treated as a generic PVM58 replacement. The critical point is that the controller must receive the same 13-bit singleturn, 12-bit multiturn, preset, counting direction, and bus-node behavior as the original encoder.
The PVM58N-YY1AGR0BN-1213 is a multiturn absolute rotary encoder with PROFIBUS interface, binary output code, aluminum housing, AG removable terminal-compartment cover, and clamping flange. The specific datasheet lists 25-bit multiturn operation, PROFIBUS profile 3.062, Class 1 and Class 2 support, speed transfer, extended scaling functions, programmable limit switches, and commissioning mode. It also defines the shaft as Ø10h8 with keyway according to DIN 6885 T1, pattern N1, tolerance P9.


The first failure boundary is scaling. This is a 25-bit configuration, not the broader 30-bit platform often associated with the PVM58 family. If the PLC project expects a different resolution per revolution, overall resolution, preset value, or cw ascending / cw descending direction, the encoder may reach Data Exchange mode while reporting a position value that no longer matches the machine travel.
This replacement fails when PROFIBUS communication is alive, but the axis stops at the wrong point because Class 2 scaling, preset, or counting direction was not copied from the original device. That is a parameter failure, not a mechanical zero problem.
The second boundary is the clamping flange and shaft load. The Ø10h8 keyed shaft must be coupled without radial or axial preload. The datasheet gives axial shaft load of 40 N and radial load of 110 N, but those values should be treated as limits, not installation targets. If the coupling is tightened before alignment is checked, the encoder can pass bus diagnostics while bearing load creates unstable position feedback.
The AG cover wiring is the third checkpoint. Bus In A/B, Bus Out A/B, 10–30 VDC, 0 V, and ground must be assigned by function. The address is set by rotary switches from 1 to 99, and the 220 Ω termination resistor must only be switched on when the encoder is the final PROFIBUS participant. Wrong A/B polarity, duplicated address, or wrong termination can stop Data Exchange even with a healthy encoder.
LED diagnostics should be checked before replacing hardware again. The datasheet separates no supply, wrong address or bus wiring, parameter/configuration error, no master communication, data timeout over 40 seconds, normal Data Exchange, and installation mode. These states are useful because they show whether the fault is wiring, parameterization, or hardware-related.
The replacement decision should first confirm 25-bit resolution mapping, Class 2 scaling, preset value, counting direction, PROFIBUS address, termination switch state, Bus In/Bus Out polarity, GSD/profile compatibility, Ø10h8 keyed shaft fit, coupling alignment, flange centering, and LED diagnostic state. EncoderWorks treats PVM58N-YY1AGR0BN-1213 as an industrial encoder custom compatible solution where PROFIBUS parameter agreement and clamping-flange mechanics must be verified together.
Typical production lead time: 15 working days.
Key Data
| Item | Data |
|---|---|
| Model | PVM58N-YY1AGR0BN-1213 |
| Encoder type | Multiturn absolute rotary encoder |
| Interface | PROFIBUS, RS-485 |
| PROFIBUS profile | PNO profile 3.062 |
| Housing | Ø58 mm industrial housing, aluminum |
| Shaft / flange | Ø10h8 keyed shaft with clamping flange |
| Connection | AG removable housing cover with terminal compartment |
| Output code | Binary |
| Resolution | 13-bit singleturn / 12-bit multiturn |
| Overall resolution | 25 bit |
| Operating voltage | 10–30 VDC |
| Transfer rate | 0.0096–12 MBit/s |
| Shaft load | Axial 40 N / radial 110 N |
| Main engineering anchor | 25-bit PROFIBUS scaling and clamping flange load |
| Main failure boundary | Wrong scaling, wrong preset, bus termination error, coupling preload |