GXM7W.110A101 RS485 Radial Connector and Clamping Flange

EncoderWorks Team
3 monthsago

GXM7W.110A101 can be supported by EncoderWorks with a custom compatible replacement focused on RS485 radial M23 pin mapping, address-coded bus identity, and Ø10 mm clamping-flange alignment. This model should not be treated as the same case as the axial connector version. The bus protocol is the same, but radial connector orientation changes cable clearance, shield routing, connector strain, and how the machine wiring enters the RS485 segment.

The GXM7W.110A101 is an RS485 multiturn absolute encoder configuration with optical sensing, 13-bit singleturn resolution, 12-bit multiturn range, binary code, 10–30 VDC supply, Ø58 mm housing, Ø10 mm clamping flange, IP54 execution, and radial M23 12-pin connector. Its position data should remain 8192 steps per turn and 4096 turns, with master/slave communication at 38.4 kBaud.

GXM7W.110A101 RS485 Radial Connector and Clamping Flange-EncoderWorks
GXM7W.110A101 RS485 Radial Connector and Clamping Flange-EncoderWorks

The first failure boundary is RS485 connector mapping. The bus uses T/R+ IN, T/R- IN, T/R+ OUT, and T/R- OUT to keep the segment free from unnecessary stub lines. If the radial M23 pins are assigned incorrectly, IN and OUT are crossed, or the final-node 150 Ω termination is not handled correctly, the encoder may power up but fail to return a stable position reply.

This replacement fails when the encoder has supply voltage, but the controller receives no valid position because radial M23 pin assignment, T/R IN/OUT wiring, Ident 1/2 address coding, or termination does not match the original installation. That is a bus-chain failure, not an optical sensing failure.

The second boundary is address and control input handling. Ident 1 and Ident 2 define the RS485 user address. Zero setting changes the electrical reference, while UP/DOWN changes the counting direction. If these lines are copied incorrectly, the reply frame may be valid while the machine position is wrong.

Mechanically, the Ø10 mm clamping flange must be centered before the coupling is tightened. Radial M23 exit needs side clearance so the connector and cable do not pull on the housing or transfer load into the shaft.

The replacement decision should first confirm Ø10 mm clamping-flange geometry, IP54 requirement, radial M23 pin assignment, RS485 38.4 kBaud setting, T/R IN and OUT wiring, final-node 150 Ω termination, Ident 1/2 address coding, 13-bit singleturn and 12-bit multiturn mapping, zero-setting input, UP/DOWN direction, supply voltage, shielding, connector clearance, and coupling load. EncoderWorks treats GXM7W.110A101 as an industrial encoder custom compatible solution where RS485 radial connector mapping and clamping-flange mechanics decide field reliability.

Typical production lead time: 15 working days.

Key Data

ItemData
ModelGXM7W.110A101
Encoder typeMultiturn absolute encoder
InterfaceRS485 bus interface
Transmission rate38.4 kBaud
Sensor technologyOptical
Resolution13-bit singleturn + 12-bit multiturn
Steps / turns8192 steps per turn / 4096 turns
CodeBinary
Supply voltage10–30 VDC
HousingØ58 mm steel housing
Shaft / flangeØ10 mm clamping flange
Protection classIP54
ConnectionA1 radial M23 12-pin connector
Control inputsZero setting, UP/DOWN direction, Ident 1/2 address coding
Main engineering anchorRS485 radial connector and clamping flange
Main failure boundaryWrong M23 pin mapping, address mismatch, termination error, coupling preload

Related Models

GXM7W.1102101 RS485 Multiturn Encoder
GXM7W.1101101 RS485 Absolute Encoder Solution
GXM7W.110A001 Multiturn Absolute Encoder

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

CEV100M-01169 SSI Multiturn Encoder Engineering Solution (ALT.:100-01169)

Previous

GXM7W.110A001 RS485 Pin Mapping and Clamping Flange

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
1423
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

UCD-DPC1B-1416-HCY0-H3P: Your Bespoke Profibus Absolute Encoder Match

UCD-DPC1B-1416-HCY0-H3P: Your Bespoke Profibus Absolute Encoder Match

EncoderWorks Team
OCD-PPA1B-0012-B12S-CAW:Parallel Encoder Replacement Solution

OCD-PPA1B-0012-B12S-CAW:Parallel Encoder Replacement Solution

EncoderWorks Team
OCD-PPA1B-0412-B14S-CRW:Parallel Encoder Replacement Solution

OCD-PPA1B-0412-B14S-CRW:Parallel Encoder Replacement Solution

EncoderWorks Team
OCF-DPC1B-1213-C10V-H3E: Seamless Integration with a Custom Profibus Encoder

OCF-DPC1B-1213-C10V-H3E: Seamless Integration with a Custom Profibus Encoder

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com