RVI70E-021K2A61N-00100 Push-Pull and 100 PPR

EncoderWorks Team
4 monthsago

RVI70E-021K2A61N-00100 Encoder with 100 PPR Check

EncoderWorks can configure RVI70E-021K2A61N-00100 as a custom compatible replacement solution for explosion-proof incremental feedback where the 100 PPR requirement, 10–30 V push-pull output, and Ø12 mm clamping-flange boundary must be confirmed together. The failure boundary is defined by non-standard pulse count, A/B/Z complementary mapping, controller scaling, 2 m axial cable routing, PE continuity, and hazardous-area sealing. Typical production lead time: 15 working days.

This model is used where low-count incremental feedback must remain stable in a protected industrial installation. Because 00100 is not listed as a standard-confirmed pulse count in the available type table, the replacement should be handled as a custom PPR confirmation case before production, even though the output circuit and mechanical code are defined.

RVI70E-021K2A61N-00100 Push-Pull and 100 PPR-EncoderWorks
RVI70E-021K2A61N-00100 Push-Pull and 100 PPR-EncoderWorks

System Limits

The first system boundary is the low-PPR scaling and push-pull counter relationship. RVI70E-021K2A61N-00100 uses A/B/Z feedback with complementary channels and a 10–30 V push-pull output circuit, but the 100 PPR suffix requires confirmation against the installed controller scaling. If the replacement is built with 512, 1000, or another assumed pulse count, the machine can fail with wrong speed feedback, proportional position error, incorrect reference behavior, or unstable counting. The controller input must also match the push-pull voltage level, channel polarity, and edge timing; otherwise the system can show missed counts, direction reversal, or Z reference loss.

The second boundary is the Ø12 mm clamping-flange installation with a 2 m axial cable in an explosion-proof housing. This version uses an aluminium body, axial cable exit, and Ø12 mm × 25 mm shaft, so shaft fit, flange face, rear cable clearance, gland stress, PE continuity, shielding, and sealing exposure must be controlled together. Excessive radial load, flange misalignment, cable pulling force, poor grounding, or damaged sealing can cause bearing stress, signal dropout, water or dust ingress, and early mechanical failure. Explosion-proof suitability must be confirmed against the installed hazardous-area requirement and certificate scope before shipment.

Wiring & Installation

Before replacement, confirm the full installed model code, actual 100 PPR requirement, controller scaling, 10–30 V supply, push-pull input compatibility, A/B/Z and complementary channel mapping, 2 m cable route, axial exit clearance, PE connection, shaft/flange dimensions, and hazardous-area requirement. The 00100 suffix should not be treated as a standard catalog pulse value until the installed unit or control setting has been checked.

During installation, the Ø12 mm clamping flange should sit flat and the coupling should not force the shaft off center. Keep the axial cable exit free from pulling force, sharp bending, or vibration load, and maintain PE and shield continuity back to the cabinet. Route encoder wiring away from motor power cables, then verify direction, Z reference behavior, and counter scaling before returning the machine to normal operation.

Custom Compatible Solution

  • Match the confirmed 100 PPR requirement, A/B/Z channel structure, and complementary signal mapping
  • Preserve 10–30 V push-pull output behavior, controller input compatibility, and edge timing
  • Adapt the Ø12 mm shaft, clamping flange, 2 m axial cable, aluminium housing, and sealing boundary
  • Review PE continuity, shaft load, cable routing, IP exposure, and hazardous-area requirement before shipment

Key Data

ItemData
ModelRVI70E-021K2A61N-00100
Encoder typeExplosion-proof incremental rotary encoder
Pulse count00100 requires confirmation
Output circuit1, 10–30 V push-pull
Signal channelsA, B, Z and complementary channels
Supply voltage10–30 V DC
Output frequencyMax. 200 kHz class boundary
ConnectionK2, 2 m cable
Cable exitA, axial
Shaft / flange021, Ø12 mm × 25 mm shaft with clamping flange
Housing materialN, aluminium
Protection classIP66 / IP67 sealing boundary requires confirmation against installed version
Hazardous-area boundaryExplosion-proof compliance requires confirmation against installed certificate scope
Key replacement checks100 PPR confirmation, push-pull input match, A/B/Z mapping, counter scaling, PE continuity, Ø12 mm shaft fit, cable gland sealing

Related Models

RVI70E-021KAR61N-00512 Incremental Encoder
RVI70E-021K2A61N-01000 Incremental Encoder Solution
RVI70E-021K5A61N-01024 Industrial Encoder
RVI70E-021K2A61N-04096 Encoder Solution
RVI70E-011K1A66I-03600 Incremental Encoder

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

RVI70E-021KAR61N-00512 Encoder with 10 m Cable Margin

Previous

RVI70E-011K5A61N-01000 Encoder with Axial Cable Margin

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
1423
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

CBE58-4096GKC11 Custom Replacement

CBE58-4096GKC11 Custom Replacement

EncoderWorks Team
OCD-PPA1B-1210-S100-CRW:Parallel Encoder Replacement Solution

OCD-PPA1B-1210-S100-CRW:Parallel Encoder Replacement Solution

EncoderWorks Team
ASM58N-F1AAARHGN-1416 Gray SSI and H Option

ASM58N-F1AAARHGN-1416 Gray SSI and H Option

EncoderWorks Team
14-14361-4096 Push-Pull Margin and Reference Pulse

14-14361-4096 Push-Pull Margin and Reference Pulse

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com