We developed a custom solution for model OCD-PPA1G-1210-C060-PRT. Selected when multi-turn absolute feedback is required via parallel push-pull output, using a 58 mm clamping flange with 6 mm solid shaft, without changing an existing parallel-control architecture. Typical production lead time: 15 working days. The referenced configuration is an optical multi-turn version with 10-bit single-turn resolution, 12-bit multi-turn resolution, Gray code, a mechanical gear-based multi-turn system without battery, 10–30 VDC supply, and an M23 26-pin radial connection.

Key Specifications

  • Interface: parallel push-pull
  • Resolution: 10-bit single-turn + 12-bit multi-turn
  • Code: Gray
  • Multi-turn: mechanical gear train, no battery
  • Supply: 10–30 VDC
  • Protection: IP65 shaft side, IP65 housing
  • Structure: 58 mm clamping flange, 6 mm solid shaft, 10 mm shaft length
  • Connection: radial M23 male, 26-pin
  • Speed: up to 12000 rpm

Decision Snapshot

  • Best for: parallel absolute retrofit systems needing multi-turn position retention
  • Key fit: 6 mm solid shaft, 58 mm clamping flange, M23 26-pin radial connection
  • Avoid if: the system is based on fieldbus communication or only requires incremental feedback; that conclusion follows from the listed parallel interface and direct bit-output structure.

Custom Solution Photos

OCD-PPA1G-1210-C060-PRT Parallel Multi-Turn Encoder, 6 mm Shaft-EncoderWorks
OCD-PPA1G-1210-C060-PRT Parallel Multi-Turn Encoder, 6 mm Shaft-EncoderWorks

Encoder structure reference: 58 mm clamping flange, 6 mm solid shaft, radial M23 26-pin connector.

Signal & Output Logic

  • Bit 1–22 parallel output
  • Includes Latch and DIR control
  • Direction configurable via cable or connector setting

Primary integration reason: the controller reads direct multi-turn absolute bit data rather than bus telegrams. Primary limitation: this architecture is efficient for parallel retrofit, but it is not suitable for Profibus, CANopen, EtherCAT, or incremental-only systems. That conclusion follows from the published 22-bit output map and push-pull interface.

Wiring & Installation

  • Connection: radial M23 male, 26-pin
  • Signals: Bit 1–22, Latch, DIR, Power Supply, GND

Primary commissioning risk: incorrect controller-side bit mapping on higher-count parallel systems. Primary installation value: the listed 12000 rpm maximum speed makes this version suitable where shaft speed matters more than bus integration. Primary mechanical constraint: the 6 mm shaft needs careful coupling alignment because small-shaft systems are less tolerant of radial and axial load error at high speed. The published shaft-load and bearing-life data support that engineering judgment.

Integration & Compatibility

  • Designed for parallel absolute encoder systems
  • Matches 58 mm clamping flange installations with 6 mm solid shaft
  • Suitable for multi-turn position feedback without battery replacement
  • Not suitable for bus-based control structures or simple incremental feedback use cases; this is a selection conclusion based on the listed interface and output type.

Lead Time

Typical production lead time: 15 working days. Custom adaptation can be developed around shaft fit, connector layout, signal assignment, and installation requirements.

Key Technical Data

ItemData
ModelOCD-PPA1G-1210-C060-PRT
InterfaceParallel push-pull
TypeAbsolute multi-turn
SensingOptical
Resolution10 bit + 12 bit
CodeGray
Multi-turnMechanical gear train
Supply10–30 VDC
ProtectionIP65
Flange58 mm clamping flange
Shaft6 mm solid
Shaft length10 mm
ConnectionRadial, M23 male, 26-pin
Speed12000 rpm
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

OCD-PPA1G-1210-S120-PRT:Parallel Encoder Replacement Solution

Previous

OCD-PPA1G-1210-C06S-PRT:Parallel Encoder Replacement Solution

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
4343
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

Absolute Encoder UCD-DPC1B-0016-HSY0-H72 | Bespoke Solutions for Your Needs

Absolute Encoder UCD-DPC1B-0016-HSY0-H72 | Bespoke Solutions for Your Needs

EncoderWorks Team
OCE-S101G-0812-W12S-HFZ Absolute Encoder - Custom Replacement & Direct Fit

OCE-S101G-0812-W12S-HFZ Absolute Encoder - Custom Replacement & Direct Fit

EncoderWorks Team
OCE-DPC1B-1416-E14W-HFZ Posital Absolute Encoders Profibus-DP (Replacement model)

OCE-DPC1B-1416-E14W-HFZ Posital Absolute Encoders Profibus-DP (Replacement model)

EncoderWorks Team
UCM-AC006-0413-E14W-HFZ Precision Replacement Absolute Encoder - Perfect Performance Match

UCM-AC006-0413-E14W-HFZ Precision Replacement Absolute Encoder - Perfect Performance Match

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com