EncoderWorks provides a custom compatible replacement solution for 1062768-01 RSA 507 focused on maintaining parallel binary output behavior, Ø6 mm shaft mounting compatibility, and singleturn position data consistency. The replacement challenge is not only matching the 13-bit absolute position output, but also preserving bit signal mapping, controller-side data interpretation, and synchro flange installation conditions. A parallel encoder can provide valid output signals while incorrect bit processing or mechanical alignment still causes position feedback errors.
System Limits
Parallel encoder replacement depends on maintaining consistent digital position transmission between the encoder and the controller. The 1062768-01 RSA 507 uses a 13-bit singleturn resolution structure with Parallel Binary output. Bit assignment, binary data interpretation, code sequence direction, and controller input compatibility must be matched because differences in signal mapping can result in incorrect position values or additional commissioning work.


The mechanical integration boundary includes shaft fit, flange mounting, and installation stability. This model uses a Ø6 mm round shaft with a synchro flange (63-type) mounting structure and a 3 m radial cable connection. Shaft alignment, flange positioning, cable routing, shielding, and grounding continuity should be maintained because mechanical mismatch or electrical interference can affect long-term position feedback reliability.
Wiring & Installation
The parallel interface requires verification of individual bit signal assignment, power supply, code sequence, and chassis shield connections. The configuration uses dedicated wiring for Bit 1 through Bit 13, 0 Volt, +E Volt, code sequence, and shield. Incorrect bit mapping, signal direction mismatch, poor shielding, or improper grounding may result in incorrect position output or unstable system operation.
During replacement installation, the Ø6 mm round shaft and synchro flange interface should be checked against the existing machine structure. The radial cable outlet, mounting stability, cable protection, and vibration conditions should be considered together to maintain reliable position measurement in industrial applications.
Custom Compatible Solution
- Match Parallel Binary output behavior and controller-side digital signal interpretation.
- Preserve 13-bit singleturn position structure and code sequence configuration.
- Adapt Ø6 mm round shaft and synchro flange (63-type) mechanical mounting requirements.
- Validate bit mapping, signal wiring, shielding, and grounding conditions.
Typical production lead time: 15 working days.
Key Data
| Parameter | Specification |
|---|---|
| Model | 1062768-01 RSA 507 |
| Encoder Type | Absolute Singleturn Encoder |
| Interface | Parallel Binary |
| Resolution | 13 bit Singleturn |
| Output Format | Binary |
| Shaft Type | Ø6 mm Round Shaft |
| Flange Type | Synchro Flange (63-Type) |
| Connection | Radial Cable |
| Cable Length | 3 m |
| Supply Voltage | 9–36 VDC |
| Protection | IP67 / IP66 |
| Main Replacement Focus | Parallel signal mapping, synchro flange adaptation, and shaft compatibility |