We have developed a custom solution for model X700.I113409.T4, configured as an incremental encoder with 250 pulses per revolution and 5 m axial cable output. This version is intended for installations where the encoder must connect over a longer fixed cable path while maintaining stable pulse output and mechanical rigidity. Since this is a non-standard custom product in limited quantity, the unit supports explosion-proof function, but it does not include an explosion-proof certificate. Typical production lead time: 15 working days.
Technical Key Parameters
- Incremental output, 250 PPR
- Supply voltage: 4.75…30 VDC
- Output signals: A, B, N + inverted
- Cable output: 5 m axial
- Protection class: IP67
Custom Solution Photos


Wiring and Installation Notes
Compared with the 2 m cable versions, this model requires more attention to cable routing, shielding continuity, and voltage stability across the longer run. Signal lines should be kept away from inverter outputs, motor cables, and switching contactors. Cable support should prevent tension from being transferred into the encoder body. The shaft and flange installation rules remain the same: concentric mounting, controlled shaft fit, and no mechanical forcing during assembly.
Custom Compatible Encoder Solution
- 250 PPR pulse output
- 5 m axial cable configuration
- Push-pull signal structure
- Suitable for installations with longer cable routing distance
Lead Time and Custom Development
This model is manufactured as a non-standard custom version. Due to limited quantity, the product supports explosion-proof function, but no explosion-proof certificate is provided. Typical production lead time: 15 working days.
Technical Parameters Table
| Layer | Item | Specification |
|---|---|---|
| Output | Encoder type | Incremental |
| Output | Pulses per revolution | 250 |
| Output | Signal format | A, B, N + inverted |
| Electrical | Supply voltage | 4.75…30 VDC |
| Electrical | Output stage | Push-pull |
| Mechanical | Shaft size | Ø10 mm |
| Mechanical | Flange | Clamping flange |
| Mechanical | Cable length | 5 m axial |
| Environmental | Protection class | IP67 |
| Environmental | Temperature class | T4 |
Technical Summary
This version combines 250 PPR incremental output with a 5 m cable layout for projects that require longer fixed cable installation.