We offer fully customizable replacement solutions for the UCM-AC005-0413-F10W-5RW absolute encoder. Our team can customize specifications, performance parameters, and dimensions to ensure compatibility with the original model or surpass its performance while ensuring seamless integration. Customization options include resolution, mechanical dimensions, and environmental protection ratings. As a reliable alternative supplier, we provide professional technical support tailored to your specific application requirements.

UCM-AC005-0413-F10W-5RW Precision Matched Encoder Replacement-EncoderWorks
UCM-AC005-0413-F10W-5RW Precision Matched Encoder Replacement-EncoderWorks

Interface

InterfaceAnalog Current
Manual FunctionsStart and End point via Cable or Connector

Electrical Data

Supply Voltage8 – 32 VDC
Current ConsumptionTypical 20 mA @24 V (no load)
Start-Up Time<500 ms
Max Load Resistance500 Ω
Analog Accuracy@ 20 mA = ±20 µA (with an ideal power supply)
Linearity0.15%
Settling Time32 ms (from min value to max value jump)
Reverse Polarity ProtectionYes
Short Circuit ProtectionYes
EMC: Emitted InterferenceDIN EN 61000-6-4
EMC: Noise ImmunityDIN EN 61000-6-2
MTTF283.3 years @ 40 °C

Sensor

TechnologyMagnetic
Resolution Singleturn13 bit
Resolution Multiturn4 bit
Multiturn TechnologySelf Powered Magnetic Pulse Counter (No Battery, Wiegand Sensor)
Accuracy (INL)±0.0878° (≤ 12 bit)
Sense Signal (Default)Counterclockwise shaft movement (front view on shaft)
CodeAnalog Current 4 – 20 mA
Minimum Measurement Range0 – 11.25°
Resolution of OutputMax. 13 bits over entire measuring range (Fractional Turns - Resolution decreases less than 13 bits when measuring range is less than 90 degrees)
Multiturn Range16 turn (default setting). User can use the scaling functionality to measure up to 32768 turns

Environmental Specifications

Protection Class (Shaft)IP66/IP67
Protection Class (Housing)IP66/IP67
Humidity98% RH, no condensation
Max Temperature+70 °C (+158 °F)
Min Temperature-30 °C fixed (-22 °F), -5 °C flexible (+23 °F)

Mechanical Data

Connection Cap MaterialStainless Steel V4A (1.4404; 316 L)
Housing MaterialStainless Steel V4A (1.4404, 316 L)
Housing CoatingNo Coating
Flange TypeClamp, ø 78 mm, ATEX
Flange MaterialStainless steel V4A (1.4404, 316 L)
Shaft TypeSolid, Single Flat, Length = 20 mm
Shaft Diameterø 10 mm (0.39")
Max. Shaft LoadAxial 60 N, Radial 80 N
Rotor Inertia≤ 35 gcm² [≤ 0.2 oz-in²]
Friction Torque≤ 3 Ncm @ 20 °C (4.2 oz-in @ 68 °F)
Max. Permissible Mechanical Speed≤ 3000 1/min
Shock Resistance≤ 100 g (half sine 11 ms, EN 60068-2-27)
Vibration Resistance≤ 10 g (10 Hz – 2000 Hz, EN 60068-2-6)
Length118 mm (4.65")
Weight2865 g (6.32 lb)

Electrical Connection

Connection OrientationRadial
Minimum Bend Radius50 mm (2") fixed, 100 mm (4") flexing
Connection TypeCable / Connector

Certification

ApprovalCE + ATEX Zone 1 & 21 (Mining)
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

UCM-AC005-0013-F10W-5RW Direct-Fit Encoder Alternative

Previous

UCM-AC006-0413-F10W-5RW Application-Specific Encoder Alternative

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
4343
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

OCD-PPA1B-0010-S06S-PRP:Parallel Encoder Replacement Solution

OCD-PPA1B-0010-S06S-PRP:Parallel Encoder Replacement Solution

EncoderWorks Team
OCE-EIC1B-0016-F12S-2RW Posital Absolute Encoders Profinet (Replacement model)

OCE-EIC1B-0016-F12S-2RW Posital Absolute Encoders Profinet (Replacement model)

EncoderWorks Team
UCD-DPC1B-1413-H8TS-H72: The Direct Custom Substitute for Profibus Absolute Encoders

UCD-DPC1B-1413-H8TS-H72: The Direct Custom Substitute for Profibus Absolute Encoders

EncoderWorks Team
CR105-4096G24C12 Parallel Technical Solution

CR105-4096G24C12 Parallel Technical Solution

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com