We developed a custom solution for model UCE-AV002-0013-E14S-HFZ. Selected when single-turn absolute position feedback is required as a 0–10 V analog voltage signal in Zone 1 & 21 oil and gas environments, using a 78 mm ATEX blind hollow structure with 14 mm shaft. Typical production lead time: 15 working days. The referenced configuration is a magnetic single-turn version with 13-bit resolution, 8–32 VDC supply, 0–10 V analog output, and CE + ATEX Zone 1 & 21 approval.

Key Specifications

  • Interface: analog voltage, 0–10 V
  • Resolution: 13-bit single-turn
  • Sensing: magnetic
  • Supply: 8–32 VDC
  • Minimum load resistance: 5 kΩ
  • Protection: IP66/IP67
  • Structure: 78 mm ATEX blind hollow, 14 mm shaft, 30 mm depth
  • Speed: up to 3000 rpm
  • Approval: CE + ATEX Zone 1 & 21 (Oil+Gas)

Decision Snapshot

  • Best for: hazardous-area analog position feedback in oil and gas systems
  • Key fit: 14 mm hollow shaft, 78 mm ATEX blind hollow flange, 0–10 V output
  • Avoid if: the project requires multi-turn retention, digital bus communication, or encoder-side network diagnostics; that follows from the listed single-turn analog output structure.

Custom Solution Photos

UCE-AV002-0013-E14S-HFZ Analog Voltage Single-Turn Encoder, 14 mm Hollow Shaft-EncoderWorks
UCE-AV002-0013-E14S-HFZ Analog Voltage Single-Turn Encoder, 14 mm Hollow Shaft-EncoderWorks

Encoder structure reference: 78 mm ATEX blind hollow flange, 14 mm shaft, radial sealed terminal layout.

Signal & Output Logic

  • Output: analog voltage 0–10 V
  • Terminals: Power Supply, GND, Analog Output
  • Set functions: Set1/Direction, Set2/Zero Set
  • Measuring range: minimum 0–11.25°

Primary integration reason: direct analog position feedback for control systems that do not require bus communication. Primary limitation: this is a single-turn analog encoder, so it is not suitable for multi-turn applications or digital network architectures. The page also notes 32 ms settling time and ±10 mV analog accuracy at 10 V under nominal supply, which makes signal conditioning and receiving-device impedance part of the selection logic.

Wiring & Installation

  • Connection: radial, 2 sealed outlets
  • Signals: Power Supply, GND, Analog Output, Set1/Direction, Set2/Zero Set
  • Startup time: < 500 ms

Primary commissioning risk: analog scaling or zero-setting errors rather than sensing failure. Primary mechanical constraint: blind hollow alignment quality in a hazardous-area installation. Best practice: control shaft tolerance, insertion depth, and receiving-side scaling together, because the encoder output is only as useful as the controller’s analog interpretation.

Integration & Compatibility

  • Designed for analog voltage position feedback in Zone 1 & 21 oil and gas environments
  • Matches 78 mm ATEX blind hollow installations with 14 mm shaft
  • Suitable for direct 0–10 V single-turn position output
  • Not suitable for multi-turn systems, pulse-only applications, or Ethernet / fieldbus architectures; this is a selection conclusion based on the listed interface, approval, and output structure.

Lead Time

Typical production lead time: 15 working days. Custom adaptation can be developed around shaft fit, analog scaling range, cable entry, and hazardous-area installation requirements.

Key Technical Data

ItemData
ModelUCE-AV002-0013-E14S-HFZ
InterfaceAnalog voltage 0–10 V
TypeAbsolute single-turn
SensingMagnetic
Resolution13 bit
Supply8–32 VDC
Output accuracy±10 mV @ 10 V
ProtectionIP66/IP67
ApprovalCE + ATEX Zone 1 & 21
Flange78 mm ATEX blind hollow
Shaft14 mm
Depth30 mm
Speed3000 rpm
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

UCE-AV002-0413-E14S-HFZ Drop-In Replacement Absolute Encoder

Previous

UCE-AV002-0413-F10S-HFZ: Direct-Fit Replacement & Custom Absolute Encoder Solution

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
4343
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

FG4K‑1024G‑90G‑NG Incremental Encoder – Customized Industrial Replacement Solution

FG4K‑1024G‑90G‑NG Incremental Encoder – Customized Industrial Replacement Solution

EncoderWorks Team
UCM-AV002-0413-E14W-2RW Analog Absolute Encoder Solution

UCM-AV002-0413-E14W-2RW Analog Absolute Encoder Solution

EncoderWorks Team
GXM7W.010A101 RS485 Mapping and IP54 Clamping Flange

GXM7W.010A101 RS485 Mapping and IP54 Clamping Flange

EncoderWorks Team
UCE-AC006-0013-F10W-CRW Seamless Fit Absolute Encoder - Custom Designed Alternative

UCE-AC006-0013-F10W-CRW Seamless Fit Absolute Encoder - Custom Designed Alternative

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com