We developed a custom solution for model UCD-DPC1B-1213-HRSS-H72. Selected when multi-turn absolute feedback is required via Profibus, using a 58 mm blind hollow structure with a 6.35 mm (1/4") shaft, without battery-based turn counting. Typical production lead time: 15 working days. The referenced configuration uses Profibus DPV0 / DPV1 / DPV2 Class 2, magnetic sensing, 13-bit single-turn resolution, 12-bit multi-turn resolution, and a self-powered magnetic pulse counter without battery or gear train.

Key Specifications

  • Interface: Profibus DPV0 / DPV1 / DPV2 Class 2
  • Resolution: 13-bit single-turn + 12-bit multi-turn
  • Code: Binary
  • Multi-turn: self-powered magnetic counter, no battery, no gear train
  • Supply: 10–30 VDC
  • Protection: IP66/IP67
  • Structure: 58 mm blind hollow, 6.35 mm shaft, 28 mm depth
  • Speed: up to 3000 rpm

Decision Snapshot

  • Best for: Profibus absolute positioning systems needing battery-free multi-turn retention
  • Key fit: 6.35 mm hollow shaft, 58 mm blind hollow flange, 28 mm insertion depth
  • Avoid if: the system only needs incremental feedback or is standardized on another motion-bus architecture; that follows from the listed Profibus-specific interface and bus-side wiring layout.

Custom Solution Photos

UCD-DPC1B-1213-HRSS-H72 Profibus Multi-Turn Encoder, 6.35 mm Hollow Shaft-EncoderWorks
UCD-DPC1B-1213-HRSS-H72 Profibus Multi-Turn Encoder, 6.35 mm Hollow Shaft-EncoderWorks

Encoder structure reference: 58 mm blind hollow flange, 6.35 mm shaft, radial M12 bus connector layout.

Bus Configuration & Communication

  • Interface class: Profibus Class 2
  • Transmission rate: up to 12 Mbaud
  • Cycle time: ≥ 1 ms
  • Functions: resolution, scaling, speed filter, preset, direction, limit switch, node number, teach mode, diagnostics

Primary integration risk: incorrect node addressing or termination-switch setup. Best practice: confirm address setting, termination status, and bus-in / bus-out continuity before power-up. That judgment is grounded in the listed address selection switch, termination DIP switch, and three-connector bus in/out layout.

Mechanical & Installation Focus

  • Housing: steel with corrosion-protective coating
  • Flange: aluminum, 58 mm blind hollow
  • Shaft: 6.35 mm hollow, 28 mm depth
  • Misalignment limits: static ±0.3 mm / ±0.5 mm, dynamic ±0.1 mm / ±0.2 mm

Primary mechanical constraint: blind hollow installation quality. Best practice: control shaft tolerance, insertion depth, and alignment stability together, not bore size alone. This matters even more on a small 1/4 inch shaft because the installation margin is narrower than on larger hollow-shaft versions. The recommendation is an engineering judgment supported by the listed misalignment limits and blind-hollow geometry.

Wiring & Bus Topology

  • Connection: radial, 3 × M12 connectors
  • Interface 1: M12 male, 4 pin, A-coded
  • Interface 2: M12 female, 5 pin, B-coded
  • Interface 3: M12 male, 5 pin, B-coded
  • Signals: Power Supply, GND, Bus line A / B for bus in and bus out

Primary commissioning issue: bus topology errors. Check sequence: address → termination → bus continuity → power. This is the correct engineering check order for the published connector and signal arrangement.

Integration & Compatibility

  • Designed for Profibus absolute encoder systems with configurable node and scaling functions
  • Matches 58 mm blind hollow installations with 6.35 mm shaft
  • Suitable for multi-turn feedback where battery-free retention is preferred
  • Not suitable for incremental-only systems or non-Profibus architectures; this is a selection conclusion based on the listed interface and wiring structure.

Lead Time

Typical production lead time: 15 working days. Custom adaptation can be developed around shaft fit, connector layout, and bus commissioning requirements.

Key Technical Data

ItemData
ModelUCD-DPC1B-1213-HRSS-H72
InterfaceProfibus
ProfileDPV0 / DPV1 / DPV2 Class 2
TypeAbsolute multi-turn
SensingMagnetic
Resolution13 bit + 12 bit
CodeBinary
Multi-turnSelf-powered magnetic counter
Supply10–30 VDC
ProtectionIP66/IP67
Flange58 mm blind hollow
Shaft6.35 mm
Depth28 mm
Speed3000 rpm
Connection3 × M12, radial

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

UCD-DPC1B-1212-HRSS-H72: A Direct Profibus Encoder Solution with Customization Options

Previous

UCD-DPC1B-1413-HRSS-H72: The Flexible Profibus Encoder Alternative with Made-to-Order Features

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
4343
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

OCF-DPC1B-0016-S12V-H3E: A Tailored Profibus Absolute Encoder Solution

OCF-DPC1B-0016-S12V-H3E: A Tailored Profibus Absolute Encoder Solution

EncoderWorks Team
HSD351024AAP HSD35 Series Incremental Encoder

HSD351024AAP HSD35 Series Incremental Encoder

EncoderWorks Team
810334-01 ISA 608 PROFIBUS M12 Connector Integration

810334-01 ISA 608 PROFIBUS M12 Connector Integration

EncoderWorks Team
G1MMH.3203P32 Absolute encoders 20 mm bore Profibus-DP (Replacement model)

G1MMH.3203P32 Absolute encoders 20 mm bore Profibus-DP (Replacement model)

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com