EncoderWorks EncoderWorks
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About
Home › Selection & Replacement › UCD-DPC1B-0016-H6Y0-H3P Profibus Single-Turn Encoder, 6 mm Hollow Shaft

UCD-DPC1B-0016-H6Y0-H3P Profibus Single-Turn Encoder, 6 mm Hollow Shaft

EncoderWorks Team
8 monthsago

We developed a custom solution for model UCD-DPC1B-0016-H6Y0-H3P. Selected when single-turn absolute feedback is required via Profibus, using a 58 mm blind hollow structure with 6 mm shaft, without adding multi-turn retention or battery-based counting. Typical production lead time: 15 working days. The referenced configuration is a Profibus DPV0 / DPV1 / DPV2 Class 2 version with magnetic sensing, 16-bit single-turn resolution, 10–30 VDC supply, and a blind hollow structure with 28 mm insertion depth.

Key Specifications

  • Interface: Profibus DPV0 / DPV1 / DPV2 Class 2
  • Resolution: 16-bit single-turn
  • Code: Binary
  • Supply: 10–30 VDC
  • Protection: IP65 shaft side, IP66/IP67 housing
  • Structure: 58 mm blind hollow, 6 mm shaft, 28 mm depth
  • Speed: up to 12000 rpm
  • Sensing: magnetic

Decision Snapshot

  • Best for: Profibus single-turn absolute positioning where compact hollow-shaft installation matters
  • Key fit: 6 mm hollow shaft, 58 mm blind hollow flange, 28 mm insertion depth
  • Avoid if: the system requires multi-turn retention, incremental-only feedback, or a non-Profibus architecture; that conclusion follows from the listed single-turn Profibus interface and connection-box topology.

Custom Solution Photos

UCD-DPC1B-0016-H6Y0-H3P Profibus Single-Turn Encoder, 6 mm Hollow Shaft-EncoderWorks
UCD-DPC1B-0016-H6Y0-H3P Profibus Single-Turn Encoder, 6 mm Hollow Shaft-EncoderWorks

Encoder structure reference: 58 mm blind hollow flange, 6 mm shaft, radial gland connection box.

Bus Configuration & Communication

  • Interface class: Profibus Class 2
  • Transmission rate: up to 12 Mbaud
  • Cycle time: ≥ 1 ms
  • Functions: resolution, scaling, speed filter, preset, direction, limit switch, node number, teach mode, diagnostics

Primary integration risk: incorrect node addressing or termination-switch setup. Best practice: confirm address setting, termination status, and bus continuity before power-up. That recommendation is grounded in the listed address-selection switch, termination DIP switch, and separate bus in / bus out layout in the connection plan.

Mechanical & Installation Focus

  • Housing: steel with corrosion-protective coating
  • Flange: aluminum, 58 mm blind hollow
  • Shaft: 6 mm hollow, 28 mm depth
  • Misalignment limits: static ±0.3 mm / ±0.5 mm, dynamic ±0.1 mm / ±0.2 mm
  • Speed capability: 12000 rpm

Primary mechanical constraint: blind hollow installation quality. Best practice: control shaft tolerance, insertion depth, and alignment stability together, not bore size alone. On this model, the small shaft diameter and high speed make mounting quality more critical than on larger hollow-shaft versions. That is an engineering judgment supported by the listed misalignment limits and speed rating.

Wiring & Bus Topology

  • Connection: radial, 3 cable glands
  • Signals: Bus line A / B, power supply, GND for bus in and bus out

Primary commissioning issue: bus topology errors rather than sensing stability. Check sequence: address → termination → bus continuity → power. That is the correct engineering check order for the published connection-box arrangement and signal map.

Integration & Compatibility

  • Designed for Profibus absolute encoder systems
  • Matches 58 mm blind hollow installations with 6 mm shaft
  • Suitable for single-turn feedback where compact hollow-shaft mounting is required
  • Not suitable for multi-turn systems or non-Profibus architectures; this is a selection conclusion based on the listed interface and wiring structure.

Lead Time

Typical production lead time: 15 working days. Custom adaptation can be developed around shaft fit, connection-box layout, and bus commissioning requirements.

Key Technical Data

ItemData
ModelUCD-DPC1B-0016-H6Y0-H3P
InterfaceProfibus
ProfileDPV0 / DPV1 / DPV2 Class 2
TypeAbsolute single-turn
SensingMagnetic
Resolution16 bit
CodeBinary
Supply10–30 VDC
ProtectionIP65 shaft / IP66-IP67 housing
Flange58 mm blind hollow
Shaft6 mm
Depth28 mm
Speed12000 rpm
ConnectionRadial, 3 cable glands

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

UCD-DPC1B-0013-HUY0-H3P Absolute Encoder: Personalized to Be Your Direct Substitute

Previous

UCD-DPC1B-0016-H8Y0-H3P: Your Custom-Configured Profibus Encoder Solution

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
4343
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

EVM78E-011DRRPBN-1416 PROFINET Ex Encoder with 30-Bit Range

EVM78E-011DRRPBN-1416 PROFINET Ex Encoder with 30-Bit Range

EncoderWorks Team
UCD-DPC1B-0013-HCY0-H3P: Your Custom Alternative Absolute Encoder for Profibus

UCD-DPC1B-0013-HCY0-H3P: Your Custom Alternative Absolute Encoder for Profibus

EncoderWorks Team
OCF-DPC1B-1416-B14S-H3E: A Bespoke-Solution Absolute Profibus Encoder

OCF-DPC1B-1416-B14S-H3E: A Bespoke-Solution Absolute Profibus Encoder

EncoderWorks Team
CEV65M-00298 SSI Radial Connector Solution

CEV65M-00298 SSI Radial Connector Solution

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com