EncoderWorks can configure OCE-EIC1B-1413-E14S-2RW as a custom compatible replacement solution for absolute multiturn Profinet feedback where device name, IP address, profile configuration, 27-bit position structure, ATEX oil-and-gas installation boundary, and Ø14 mm blind-hollow fit must remain aligned with the installed PLC project. The failure boundary is not only the 10–32 VDC supply, but also GSDML compatibility, Rx/Tx wiring, fractional scaling, preset behavior, counting direction, commissioning diagnostics, and hazardous-area approval scope. Typical production lead time: 15 working days.

This model is used where the control system reads absolute multiturn position over a Profinet network in a Zone 1 & 21 oil-and-gas hazardous-area installation. A compatible replacement must preserve the 13-bit singleturn and 14-bit multiturn position structure, Binary position handling inside the device, Profinet device identity, profile behavior, radial communication wiring, and Ø14 mm blind-hollow mechanical interface.

OCE-EIC1B-1413-E14S-2RW Profinet ATEX Profile Boundary-EncoderWorks
OCE-EIC1B-1413-E14S-2RW Profinet ATEX Profile Boundary-EncoderWorks

System Limits

The first system boundary is the Profinet network and profile configuration. OCE-EIC1B-1413-E14S-2RW works through Profinet profile behavior rather than discrete data bits, so the PLC project must see the same device name, IP address behavior, GSDML compatibility, profile class expectation, resolution parameter, fractional scaling, counting direction, preset function, velocity filtering, and diagnostic response. If the replacement is installed with a different device identity, incompatible configuration file, changed parameter length, wrong scaling, or mismatched direction setting, the network may detect a device while the axis reports wrong position, wrong direction, invalid scaling, synchronization faults, or unstable commissioning status.

The second boundary is the Ethernet physical layer and hazardous-area mechanical structure. Rx/Tx line assignment, supply reference, GND integrity, shielding, cable bend radius, radial connection clearance, and grounding must match the installed machine. A correct encoder can still fail if Rx/Tx pairs are crossed incorrectly, shielding is interrupted, the power reference is unstable, or the cable / connector route compromises the ATEX sealing boundary.

Wiring & Installation

Before replacement, confirm the full installed model code, Profinet device name, IP address requirement, GSDML requirement, Profidrive or Encoder Profile use, resolution setting, fractional scaling, preset requirement, counting direction, velocity filtering, diagnostic mapping, and PLC commissioning method. Do not treat this as a Bit Parallel, Profibus, EtherNet/IP, or incremental replacement, because the controller is reading a configured Profinet device rather than separate data bits, a fieldbus node, a CIP object, or an A/B/Z pulse train.

The blind-hollow installation must also be checked carefully. The Ø14 mm hollow shaft, 30 mm insertion depth, ATEX flange interface, clamping condition, torque restraint, radial cable clearance, static and dynamic misalignment, and grounding continuity can affect long-term stability. Poor clamping, excessive shaft offset, cable strain, connector stress, or shield discontinuity can cause communication faults, mechanical drift, intermittent diagnostics, or early bearing wear. Hazardous-area suitability must be confirmed against the installed Zone 1 & 21 oil-and-gas requirement and certificate scope before shipment.

Custom Compatible Solution

  • Match Profinet device behavior, 13-bit singleturn plus 14-bit multiturn feedback, profile expectations, and device-name / IP-address requirement
  • Preserve GSDML compatibility, Rx/Tx communication wiring, supply reference, GND integrity, shield continuity, preset behavior, and fractional scaling
  • Adapt the Ø14 mm blind-hollow shaft, 30 mm depth, 78 mm ATEX flange class, radial connection route, and sealing boundary
  • Review profile parameter mapping, diagnostics, counting direction, velocity filtering, oil-and-gas hazardous-area scope, and shaft misalignment before shipment

Key Data

ItemData
ModelOCE-EIC1B-1413-E14S-2RW
Encoder typeAbsolute multiturn rotary encoder for Zone 1 & 21 oil-and-gas installation
InterfaceProfinet
Profile / classProfidrive Profile 4.x; Encoder Profile 4.0, 4.1, 4.2
Transmission rate100 Mbit
Interface cycle time≥125 µs
Supply voltage10–32 VDC
Output driverEthernet
Sensor technologyOptical
Singleturn resolution13 bit
Multiturn resolution14 bit
Total position structure27-bit absolute multiturn data
CodeBinary
Multiturn technologyMechanical gearing, no battery
Programming functionsResolution, velocity time base/filter, preset, counting direction, IP address, fractional scaling, parameter control via GSDML or non-volatile memory
DiagnosticsMemory, temperature, synchronization, commissioning diagnostics, invalid scaling, communication, master sign of life
ConnectionCable / connector
Connection orientationRadial
Shaft / flangeBlind hollow, Ø14 mm shaft, 30 mm depth, 78 mm ATEX flange class
Protection classIP66 / IP67 boundary requires confirmation against installed version
Hazardous-area boundaryZone 1 & 21 oil-and-gas compliance requires confirmation against installed certificate scope
Key replacement checksDevice name, IP address, GSDML, profile parameters, Rx/Tx wiring, fractional scaling, preset, direction, Ø14 mm blind-hollow fit, ATEX certificate scope
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

OCE-EIC1B-1416-E14S-2RW Posital Absolute Encoders Profinet (Replacement model)

Previous

OCE-EIC1B-1213-E14S-2RW Posital Absolute Encoders Profinet (Replacement model)

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
4343
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

OCF-DPC1B-1216-B12S-H3E: Personalize Your Profibus Absolute Encoder

OCF-DPC1B-1216-B12S-H3E: Personalize Your Profibus Absolute Encoder

EncoderWorks Team
OCD-PPA1G-0010-S06S-PRP:Parallel Encoder Replacement Solution

OCD-PPA1G-0010-S06S-PRP:Parallel Encoder Replacement Solution

EncoderWorks Team
OCE-EIC1B-1216-E14S-CRW Posital Absolute Encoders Profinet (Replacement model)

OCE-EIC1B-1216-E14S-CRW Posital Absolute Encoders Profinet (Replacement model)

EncoderWorks Team
OCD-DPC1B-0016-B150-H3P Profibus Encoder: The Bespoke Alternative for Your System

OCD-DPC1B-0016-B150-H3P Profibus Encoder: The Bespoke Alternative for Your System

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com