We developed a custom solution for model OCD-PPA1G-1210-B100-CRW. Selected when multi-turn absolute feedback is required via parallel push-pull output, using a 58 mm blind hollow structure with 10 mm shaft, without changing an existing parallel-control architecture. Typical production lead time: 15 working days. The referenced configuration is an optical multi-turn version with 10-bit single-turn resolution, 12-bit multi-turn resolution, Gray code, a mechanical gear-based multi-turn system without battery, 10–30 VDC supply, and IP65 protection.

Key Specifications

  • Interface: parallel push-pull
  • Resolution: 10-bit single-turn + 12-bit multi-turn
  • Code: Gray
  • Multi-turn: mechanical gear train, no battery
  • Supply: 10–30 VDC
  • Protection: IP65
  • Structure: 58 mm blind hollow, 10 mm shaft, 30 mm depth
  • Speed: up to 12000 rpm

Decision Snapshot

  • Best for: parallel absolute retrofit systems needing multi-turn position retention
  • Key fit: 10 mm hollow shaft, 58 mm blind hollow flange, 30 mm insertion depth
  • Avoid if: the system is based on fieldbus communication or only requires incremental feedback; that conclusion follows from the listed parallel interface and direct bit-output structure.

Custom Solution Photos

OCD-PPA1G-1210-B100-CRW Parallel Multi-Turn Encoder, 10 mm Hollow Shaft-EncoderWorks
OCD-PPA1G-1210-B100-CRW Parallel Multi-Turn Encoder, 10 mm Hollow Shaft-EncoderWorks

Encoder structure reference: 58 mm blind hollow flange, 10 mm shaft, radial cable outlet.

Signal & Output Logic

The product page lists a parallel push-pull interface with direct bit-mapped output. That makes this version suitable when the controller reads absolute position through parallel lines rather than bus telegrams. Its main limitation is the same architecture choice: it is efficient for parallel retrofit, but it is not suitable for Profibus, CANopen, EtherCAT, or incremental-only systems.

Wiring & Installation

Primary installation value: the listed 12000 rpm maximum speed makes this version suitable where shaft speed matters more than bus integration. Primary mechanical constraint: blind hollow installation quality. The page also lists static and dynamic axial/radial misalignment limits, so shaft tolerance, insertion depth, and alignment stability should be controlled together, not bore size alone.

Integration & Compatibility

  • Designed for parallel absolute encoder systems
  • Matches 58 mm blind hollow installations with 10 mm shaft
  • Suitable for multi-turn position feedback without battery replacement
  • Not suitable for bus-based control structures or simple incremental feedback use cases; this is a selection conclusion based on the listed interface and multi-turn output structure.

Lead Time

Typical production lead time: 15 working days.

Key Technical Data

ItemData
ModelOCD-PPA1G-1210-B100-CRW
InterfaceParallel push-pull
TypeAbsolute multi-turn
SensingOptical
Resolution10 bit + 12 bit
CodeGray
Multi-turnMechanical gear train
Supply10–30 VDC
ProtectionIP65
Flange58 mm blind hollow
Shaft10 mm
Depth30 mm
Speed12000 rpm

The table above is compiled from the product page’s electrical, sensing, mechanical, and environmental data.

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

OCD-PPA1G-1210-B12S-CRW:Parallel Encoder 1:1 Replacement

Previous

OCD-PPA1G-1210-SB90-CRW:Parallel Encoder 1:1 Replacement

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
4343
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

Replacement Solution for OCE-CAA1B-1212-F100-HFE | Tailored Fit, Superior Performance

Replacement Solution for OCE-CAA1B-1212-F100-HFE | Tailored Fit, Superior Performance

EncoderWorks Team
AVS78E-011K5R0GN-0012 SSI K5 Radial Cable Timing

AVS78E-011K5R0GN-0012 SSI K5 Radial Cable Timing

EncoderWorks Team
UCD-EIC1B-0013-L100-PRM: Custom-Fit Absolute Encoder Solution

UCD-EIC1B-0013-L100-PRM: Custom-Fit Absolute Encoder Solution

EncoderWorks Team
OCD-PPA1G-0012-B10S-CRW:Parallel Encoder 1:1 Replacement

OCD-PPA1G-0012-B10S-CRW:Parallel Encoder 1:1 Replacement

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com