EncoderWorks EncoderWorks
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About
Home › Selection & Replacement › OCD-EEC1B-1213-S06S-PCM EtherNet/IP Absolute Encoder, 6 mm Shaft

OCD-EEC1B-1213-S06S-PCM EtherNet/IP Absolute Encoder, 6 mm Shaft

EncoderWorks Team
10 monthsago

We developed a custom solution for model OCD-EEC1B-1213-S06S-PCM. Selected when multi-turn absolute feedback is required via EtherNet/IP, using a 58 mm synchro flange with 6 mm solid shaft, without battery replacement in long-cycle positioning systems. Typical production lead time: 15 working days. The referenced configuration combines EtherNet/IP, 13-bit single-turn resolution, 12-bit multi-turn resolution, and a mechanical gear-based multi-turn system without battery.

Key Specifications

  • Interface: EtherNet/IP
  • Profile: CIP
  • Resolution: 13-bit single-turn + 12-bit multi-turn
  • Code: Binary
  • Multi-turn: mechanical gear train, no battery
  • Supply: 10–30 VDC
  • Protection: IP66/IP67
  • Structure: 58 mm synchro flange, 6 mm solid shaft, 10 mm shaft length
  • Connection: radial + 3 rotary switches + M25, M12 network connectors
  • Speed: up to 3000 rpm
  • Temperature range: -40 °C to +85 °C

Decision Snapshot

  • Best for: EtherNet/IP motion systems needing compact multi-turn absolute feedback
  • Key fit: 6 mm shaft
  • Avoid if: the application requires parallel wiring simplicity, analog output, or non-EtherNet/IP communication, because this model is built around CIP network integration and multi-turn Ethernet feedback.

Custom Solution Photos

OCD-EEC1B-1213-S06S-PCM EtherNet/IP Absolute Encoder, 6 mm Shaft-EncoderWorks
OCD-EEC1B-1213-S06S-PCM EtherNet/IP Absolute Encoder, 6 mm Shaft-EncoderWorks

Encoder structure reference: 58 mm synchro flange, 6 mm solid shaft, radial M12 network connector layout.

Bus Configuration & Communication

The interface is EtherNet/IP with CIP, 100 Mbit transmission, interface cycle time from 1 ms, and programmable functions including resolution, time base and velocity filter, preset, counting direction, parameter control priority, and IP address. Error and warning bits are also available.

Primary integration value: network-based multi-turn absolute position with controller-side diagnostics and standard Ethernet infrastructure.
Primary risk: network configuration, switch setup, or controller mapping errors rather than signal-line noise from multi-wire parallel outputs.
Best practice: power → port continuity → IP recognition → controller mapping. That is the practical startup sequence for this connector-based EtherNet/IP structure.

Mechanical & Installation Focus

This version uses a steel housing with corrosion-protective coating, 58 mm synchro flange, and 6 mm solid stainless shaft. Published shaft load is 40 N axial / 110 N radial, with maximum mechanical speed of 3000 rpm.

Primary mechanical constraint: the 6 mm shaft is less forgiving than larger solid-shaft versions.
Primary installation value: compact shaft diameter with Ethernet communication in a small industrial package.
At this shaft size, coupling alignment still matters because radial and axial loading will affect bearing life much earlier than in larger shaft classes. That conclusion follows from the shaft size and published load data.

Wiring & Bus Topology

The electrical connection uses radial M12 connectors plus rotary switch hardware. Interface 1 is M12 female 4-pin D-coded, Interface 2 is M12 male 4-pin A-coded, and Interface 3 is M12 female 4-pin D-coded.

Primary commissioning issue: network recognition and parameter assignment.
Check sequence: power → port integrity → node recognition → parameter setup.
This model reduces multi-line signal mapping, but successful startup depends more on Ethernet commissioning discipline than on encoder hardware.

Integration & Compatibility

  • Designed for EtherNet/IP absolute encoder systems
  • Matches 58 mm synchro flange installations with 6 mm solid shaft
  • Suitable for multi-turn feedback where compact mechanics and Ethernet communication are both required
  • Not suitable for fieldbus-incompatible or non-network architectures

Lead Time

Typical production lead time: 15 working days. Custom adaptation can be developed around shaft fit, connector layout, and network integration requirements.

Key Technical Data

ItemData
ModelOCD-EEC1B-1213-S06S-PCM
InterfaceEtherNet/IP
ProfileCIP
TypeAbsolute multi-turn
SensingOptical
Resolution13 bit + 12 bit
CodeBinary
Multi-turnMechanical gear train
Supply10–30 VDC
ProtectionIP66/IP67
Flange58 mm synchro flange
Shaft6 mm solid
Shaft length10 mm
ConnectionRadial M12 + switch layout
Speed3000 rpm
EncoderWorks Technical Support

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: encoderworks@outlook.com

EncoderWorks Technical Support

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: encoderworks@outlook.com

OCD-EEC1B-1216-S06S-PCM:EtherNet Encoder Replacement Solution

Previous

OCD-EEC1B-1416-SA10-PCM EtherNet/IP DLR and Synchro Shaft Fit

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 ( WhatsApp) Email:encoderworks@outlook.com
4343
Posts
0
Comments
0
Likes

Articles

CMV58M-00005 PROFIBUS-DP Absolute Encoder
ATM60-PAH13X13 PROFIBUS-DP Absolute Encoder
CEV65M-01646 PROFIBUS-DP Absolute Encoder
ENA58PL-S10CA7-1213B17-RH2 PROFINET Absolute Encoder

Related posts

UCD-DPC1B-1416-HST0-H3P: Engineered as Your Direct Profibus Encoder Substitute

UCD-DPC1B-1416-HST0-H3P: Engineered as Your Direct Profibus Encoder Substitute

EncoderWorks Team
OCD-PPA1B-0810-B12S-PRT:Parallel Encoder 1:1 Replacement

OCD-PPA1B-0810-B12S-PRT:Parallel Encoder 1:1 Replacement

EncoderWorks Team
OCD-DPC1B-1416-B06S-H72: Configure Your Perfect Fit Profibus Encoder

OCD-DPC1B-1416-B06S-H72: Configure Your Perfect Fit Profibus Encoder

EncoderWorks Team
OCE-S101B-0812-E140-HFZ Drop-In Replacement | Fully Compatible Custom Absolute Encoder

OCE-S101B-0812-E140-HFZ Drop-In Replacement | Fully Compatible Custom Absolute Encoder

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

encoderworks@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 ( WhatsApp) Email:encoderworks@outlook.com