Home › Selection & Replacement › EVS78E-011KRRPBN-0013 PROFINET 13-Bit KR Terminal Mapping

EVS78E-011KRRPBN-0013 PROFINET 13-Bit KR Terminal Mapping

EncoderWorks Team
1 yearago

EncoderWorks develops the EVS78E-011KRRPBN-0013 custom compatible replacement solution around explosion-proof PROFINET singleturn feedback where 13-bit position data, RT/IRT timing, Ethernet Rx/Tx terminal mapping, KR cable-gland sealing, aluminum grounding, and Ø10 mm clamping-flange coupling must remain matched to the installed PLC project. The failure boundary is not only the 10–30 VDC supply, but also device identity, 100 MBit/s PROFINET communication, binary singleturn data length, Rx-/Tx-/Rx+/Tx+ polarity, shield continuity, flange seating, and explosion-proof certificate scope. Typical production lead time: 15 working days.

This model is used where the controller reads absolute singleturn position over a PROFINET network from a solid-shaft encoder with a radial KR terminal compartment and aluminum housing. A compatible replacement must preserve the 13-bit singleturn position structure, binary code behavior, Ethernet terminal assignment, PLC project recognition, Ø10 mm shaft interface, clamping-flange geometry, housing ground path, cable-gland sealing, stopping-plug boundary, and hazardous-area installation requirement.

EVS78E-011KRRPBN-0013 PROFINET 13-Bit KR Terminal Mapping-EncoderWorks
EVS78E-011KRRPBN-0013 PROFINET 13-Bit KR Terminal Mapping-EncoderWorks

System Limits

The first system boundary is the PROFINET project and 13-bit singleturn data structure. EVS78E-011KRRPBN-0013 must appear to the PLC as the correct PROFINET singleturn encoder device with matching device identity, network configuration, RT/IRT timing expectation, counting direction, diagnostic behavior, and 13-bit binary position length. If the replacement is supplied as a multiturn device, configured with a different data length, assigned with incompatible device identity, or commissioned with changed direction behavior, the network may still detect an Ethernet device while the axis reports the wrong angle, unstable diagnostics, incorrect direction, or commissioning mismatch.

The second boundary is the KR radial terminal compartment and Ø10 mm clamping-flange installation. Terminal 1 GND, terminal 2 +Ub, terminal 5 Rx-, terminal 6 Tx-, terminal 7 Rx+, terminal 8 Tx+, grounding terminal, shield path, one cable gland, stopping plug, radial cable clearance, and aluminum housing bonding must match the installed wiring. A correct PROFINET encoder can still fail if Rx/Tx pairs are crossed, polarity is reversed, unused terminals are treated as active signals, the shield is terminated with high impedance, or the stopping plug does not preserve the sealing boundary. Mechanically, the Ø10 mm × 20 mm solid shaft, clamping flange, coupling alignment, axial load, radial load, and shaft-load boundary must be checked together.

Wiring & Installation

Before replacement, confirm the full installed model code, PROFINET device identity requirement, PLC project configuration, 13-bit singleturn structure, RT/IRT timing requirement, counting direction, diagnostic mapping, KR terminal layout, radial cable-entry direction, cable-gland condition, stopping-plug condition, aluminum housing requirement, clamping-flange geometry, and Ø10 mm shaft interface. This KR version should not be inferred from DR variants because the cable-entry count, sealing boundary, strain relief, shield termination path, and unused port condition are different.

During installation, verify supply wiring, GND, Rx-/Tx-/Rx+/Tx+ terminal assignment, grounding terminal, shield continuity, and Ethernet cable routing before powering the system. Keep PROFINET wiring away from motor and drive cables, avoid cable kinking or tensile load at the gland, and maintain low-impedance bonding through the terminal compartment. The clamping flange should seat flat, and the coupling should not force the Ø10 mm shaft off center. Explosion-proof suitability must be confirmed against the installed hazardous-area requirement and certificate scope before shipment.

Custom Compatible Solution

  • Match PROFINET communication behavior, 13-bit singleturn feedback, binary code, RT/IRT timing expectation, and PLC project requirements
  • Preserve GND, +Ub, Rx-, Tx-, Rx+, Tx+, grounding terminal, shield continuity, KR cable-gland sealing, and stopping-plug boundary
  • Adapt the Ø10 mm × 20 mm solid shaft, clamping flange, KR radial terminal compartment, aluminum housing, and IP66 sealing boundary
  • Review device identity, 13-bit process-data length, Ethernet terminal mapping, clamping-flange seating, housing bonding, hazardous-area certificate scope, and commissioning requirements before shipment

Key Data

ItemData
ModelEVS78E-011KRRPBN-0013
Encoder typeExplosion-proof singleturn absolute rotary encoder
InterfacePROFINET
Transmission rate100 MBit/s
Timing boundaryRT / IRT timing requires PLC project confirmation
Supply voltage10–30 VDC
Output codeBinary
Singleturn resolution13 bit
Multiturn resolutionNot applicable
Total position structure13-bit absolute singleturn data
ConnectionKR, terminal compartment with 1 cable gland and 1 stopping plug
Cable exitR, radial
Ethernet terminal boundaryRx-, Tx-, Rx+, Tx+ mapping requires confirmation before replacement
Shaft / flangeØ10 mm × 20 mm solid shaft, clamping flange
Housing materialN, aluminum
Protection classIP66 sealing boundary requires confirmation against installed version
Hazardous-area boundaryATEX / IECEx explosion-proof compliance requires confirmation against installed certificate scope
Key replacement checksDevice identity, PLC project match, RT/IRT timing, 13-bit data length, Rx/Tx terminal mapping, shield continuity, KR sealing, aluminum grounding, Ø10 mm clamping-flange coupling
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

PSM78E-F5AK2R0BN-1213 PROFIBUS F5A Hollow-Shaft Bus Boundary

Previous

EVS78E-011DRRPBN-0013 PROFINET 13-Bit DR Clamping Mapping

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
1423
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

UCD-DPC1B-1212-HFSS-H72: Made-to-Order Profibus Encoder for Perfect Integration

UCD-DPC1B-1212-HFSS-H72: Made-to-Order Profibus Encoder for Perfect Integration

EncoderWorks Team
GAMX12-1500-003:GAMX_12//5G59//01500//GPA030 Encoder Technical Solution

GAMX12-1500-003:GAMX_12//5G59//01500//GPA030 Encoder Technical Solution

EncoderWorks Team
UCD-DPC1B-1213-HRTS-H3P: The Adaptable Choice for Profibus Encoder Needs

UCD-DPC1B-1213-HRTS-H3P: The Adaptable Choice for Profibus Encoder Needs

EncoderWorks Team
OCM-DPC1B-0013-W10W-HFZ Posital Absolute Encoders Profibus-DP (Replacement model)

OCM-DPC1B-0013-W10W-HFZ Posital Absolute Encoders Profibus-DP (Replacement model)

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com