For 8.A227.F324.G323, EncoderWorks can provide a custom compatible replacement solution for large-shaft SSI absolute encoder systems where the key checks are ø28 mm H7 bore fit, torque-arm-side locking-ring access, 70 mm torque-arm preload, SSI Gray-code timing, and radial M23 connector wiring. This model should not be treated like the ø20 mm 150 mm-arm version, because both the bore size and torque-arm length change the mechanical installation boundary. Typical production lead time: 15 working days.

This configuration combines a Kübler AX hollow-shaft adapter with a Sendix F5863 absolute multiturn encoder. The AX section provides the ø28 mm hollow-shaft bore, locking ring on the torque-arm side, and 70 mm torque arm, while the encoder body provides 13-bit singleturn plus 12-bit multiturn position feedback through an SSI Gray-code interface and one radial M23 connector. Replacement work should focus on shaft fit, clamp access, clamping torque, torque-arm alignment, SSI clock frequency, data polarity, Gray-code interpretation, preset or setting-button behavior, and shield grounding.

8.A227.F324.G323 SSI Encoder with Ø28 mm AX Adapter-EncoderWorks
8.A227.F324.G323 SSI Encoder with Ø28 mm AX Adapter-EncoderWorks

System Limits

The first system limit is SSI timing. The controller must match the expected SSI clock, data polarity, bit length, and Gray-code interpretation. If the clock timing, bit order, or code conversion is wrong, the encoder may transmit stable data while the controller calculates the wrong absolute position.

The second limit is AX mechanical installation. The ø28 mm shaft must match the H7 adapter bore without forcing the clamp, and the locking ring must be accessible from the torque-arm side. Shaft runout, excessive clamp force, or torque-arm preload can create bearing load, housing movement, or repeatability drift.

The third limit is the AX operating envelope. The adapter is rated IP64 and has temperature-dependent speed limits. High shaft speed, high ambient temperature, or a loaded torque arm can become the practical failure boundary even when the SSI signal remains electrically stable.

Wiring & Installation

Before replacement, record the SSI clock/data wiring, supply voltage, ground, shield connection, bit length, code type, counting direction, preset value, and any setting-button or LED diagnostic behavior used by the machine. Also record the radial M23 connector pin assignment before removing the existing encoder.

During installation, confirm the ø28 mm H7 shaft fit, keep the locking ring on the torque-arm side, and align the 70 mm torque arm without preload. Route SSI and power cables away from inverter output wiring, maintain shield continuity through the M23 connector, and avoid ground loops between the encoder housing, machine frame, and cabinet earth. After startup, verify absolute position value, direction, repeatability, preset response, torque-arm movement, and stable data reading over several machine cycles.

Custom Compatible Solution

EncoderWorks can configure the replacement around the installed shaft and SSI control system:

  • Match the AX ø28 mm hollow-shaft adapter, torque-arm-side locking ring, 70 mm torque arm, and mounting envelope
  • Preserve Sendix F5863 SSI Gray-code feedback, 13-bit singleturn plus 12-bit multiturn scaling, and controller data interpretation
  • Adapt the radial M23 connector layout, 10–30 VDC supply range, SSI clock/data wiring, and shield grounding
  • Review clamp torque, shaft fit, torque-arm preload, IP64 installation limits, and temperature-speed operating margin

Key Data

ItemData
Model8.A227.F324.G323
Encoder typeAbsolute multiturn encoder with AX hollow-shaft adapter
Encoder bodySendix F5863
InterfaceSSI
Resolution13-bit singleturn + 12-bit multiturn
CodeSSI Gray code
Supply voltage10–30 VDC
Boreø28 mm H7 hollow-shaft adapter
Locking ring positionTorque-arm side
Torque arm70 mm
Connection1× radial M23 connector
Adapter protectionIP64
Adapter weightApprox. 3.5 kg
Starting torqueMax. 0.15 Nm at 23°C
Special optionSetting button + status LED
EncoderWorks Technical Support

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: encoderworks@outlook.com

EncoderWorks Technical Support

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: encoderworks@outlook.com

8.A245.F324.G323 SSI Encoder with Ø25 mm AX Adapter

Previous

8.A262.F324.G323 SSI Encoder with 150 mm AX Torque Arm

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 ( WhatsApp) Email:encoderworks@outlook.com
1444
Posts
0
Comments
0
Likes

Articles

CMV58M-00005 PROFIBUS-DP Absolute Encoder
ATM60-PAH13X13 PROFIBUS-DP Absolute Encoder
CEV65M-01646 PROFIBUS-DP Absolute Encoder
ENA58PL-S10CA7-1213B17-RH2 PROFINET Absolute Encoder

Related posts

OCD-PPA1B-0412-S100-PRT:Parallel Encoder Replacement Solution

OCD-PPA1B-0412-S100-PRT:Parallel Encoder Replacement Solution

EncoderWorks Team
OCF-DPC1B-0012-C12V-H3E Profibus Single-Turn Encoder, 12 mm Shaft

OCF-DPC1B-0012-C12V-H3E Profibus Single-Turn Encoder, 12 mm Shaft

EncoderWorks Team
OCF-DPC1B-1412-SB90-H3E: Made-to-Order Encoder Replacement

OCF-DPC1B-1412-SB90-H3E: Made-to-Order Encoder Replacement

EncoderWorks Team
GAMX12-1000-002:GAMX_12//5G59//10000//GPA030 Encoder Technical Solution

GAMX12-1000-002:GAMX_12//5G59//10000//GPA030 Encoder Technical Solution

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

encoderworks@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 ( WhatsApp) Email:encoderworks@outlook.com