8.A122.6832.3113 Profibus Encoder with AX Ø20 mm Hollow-Shaft Adapter

EncoderWorks Team
12 monthsago

For 8.A122.6832.3113, EncoderWorks can provide a custom compatible replacement solution for large-shaft Profibus absolute feedback systems where the key checks are AX ø20 mm bore fit, encoder-side locking-ring position, 70 mm torque-arm preload, Profibus-DP scaling, and M12 network wiring. This model should not be treated like the ø16 mm version, because the adapter bore changes to ø20 mm and the clamp fit becomes the first mechanical replacement boundary. Typical production lead time: 15 working days.

This configuration is used where a Profibus absolute encoder must be mounted directly on a larger machine shaft rather than through a small solid-shaft coupling. The AX section provides a ø20 mm hollow-shaft adapter, encoder-side clamping, and 70 mm torque arm, while the matched Sendix 5868 encoder provides Profibus-DP V0 Class 2 absolute position feedback through three radial M12 connectors. Replacement work should focus on shaft fit, clamping torque, torque-arm alignment, Profibus address, GSD configuration, scaling, preset behavior, and shield continuity.

8.A122.6832.3113 Profibus Encoder with AX Ø20 mm Hollow-Shaft Adapter-EncoderWorks
8.A122.6832.3113 Profibus Encoder with AX Ø20 mm Hollow-Shaft Adapter-EncoderWorks

System Limits

The first system limit is mechanical. The ø20 mm shaft must match the AX adapter bore without forcing the clamp, and the locking ring must remain on the encoder side as specified by the A1 configuration. Excess clamp force, shaft runout, or torque-arm preload can create bearing stress, housing movement, or repeatability drift.

The second limit is Profibus configuration. The PLC must recognize the replacement as the correct Profibus-DP encoder class and preserve the original address, GSD file, scaling, preset value, and counting direction. If the bus is online but scaling or profile data is different, the axis may report a valid position with the wrong mechanical value.

The third limit is AX operating envelope. The AX adapter is rated IP64 and its allowable speed depends on operating temperature. High shaft speed, high ambient temperature, or poor torque-arm alignment can become the real failure boundary before the electrical interface fails.

Wiring & Installation

Before replacement, record the Profibus node address, GSD configuration, preset value, scaling parameters, direction setting, and diagnostic behavior from the controller project. Also record the three M12 connector assignments for Profibus bus, power supply, and service or auxiliary wiring.

During installation, confirm the ø20 mm H7 shaft fit, set the locking ring on the encoder side, and align the 70 mm torque arm without preload. Keep the Profibus and power cables away from inverter output wiring, maintain shield continuity through the M12 connectors, and avoid ground loops between the encoder housing, machine frame, and cabinet earth. After startup, verify online bus status, actual position, direction, preset response, torque-arm movement, and repeatability over several machine cycles.

Custom Compatible Solution

EncoderWorks can configure the replacement around the installed shaft and Profibus system:

  • Match the AX ø20 mm hollow-shaft adapter, encoder-side locking ring, 70 mm torque arm, and installation envelope
  • Preserve Sendix 5868 Profibus-DP V0 Class 2 position feedback, GSD setup, scaling, preset, and direction behavior
  • Adapt the three radial M12 connection layout, power supply range, shield grounding, and bus wiring
  • Review clamping torque, shaft fit, torque-arm preload, IP64 installation limits, and temperature-speed operating margin

Key Data

ItemData
Model8.A122.6832.3113
Encoder typeAbsolute multiturn encoder with AX hollow-shaft adapter
Encoder bodySendix 5868
InterfaceProfibus-DP V0, encoder protocol Class 2
Supply voltage10–30 VDC
Boreø20 mm hollow-shaft adapter
Locking ring positionEncoder side
Torque arm70 mm
Connection3× radial M12 connectors
Adapter protectionIP64
Adapter weightApprox. 3.5 kg
Special optionSet button
Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

Industrial Encoder Technical Consultant

Contact Support

WeChat: +86 150 5045 0799 (WhatsApp)

Email: sividi360@outlook.com

8.A122.6832.3113 Profibus Encoder with Ø20 mm AX Adapter

Previous

8.A121.6832.3113 Profibus Encoder with AX Ø16 mm Hollow-Shaft Adapter

Next

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com
1423
Posts
0
Comments
0
Likes

Articles

67-11616-1024 and 67-11617-1024 1024 Incremental Encoder Signal Boundary
OG73 UN 1024 and OG73 RN 1024 Compact Housing Boundary
CEV65S-00169 Profibus Encoder with ZB80 Flange (111-00169)
PAMM90A10-BF6XXR-4096/8192 Profibus-DP and Ø10 Round Flange

Related posts

OCD-PPA1G-00AA-B11S-5AW Parallel Encoder with Latch Wiring

OCD-PPA1G-00AA-B11S-5AW Parallel Encoder with Latch Wiring

EncoderWorks Team
CE58-1024GB06 Custom Solution

CE58-1024GB06 Custom Solution

EncoderWorks Team
OCD-PPA1G-0012-C06S-CRW:Parallel Encoder 1:1 Replacement

OCD-PPA1G-0012-C06S-CRW:Parallel Encoder 1:1 Replacement

EncoderWorks Team
UCD-DPC1B-0012-L120-H72: Seamless Integration with Your Custom Profibus Encoder Solution

UCD-DPC1B-0012-L120-H72: Seamless Integration with Your Custom Profibus Encoder Solution

EncoderWorks Team

About

EncoderWorks focuses on industrial encoder technology, interface compatibility, and system integration.

Column

Home Fundamentals Selection & Replacement Applications Fault Diagnosis Contact

Contact

sividi360@outlook.com
© 2026 EncoderWorks. All rights reserved.
  • Home
  • Fundamentals
  • Applications
  • Selection & Replacement
  • Fault Diagnosis
  • About

EncoderWorks Team

WeChat:+86 150 5045 0799 (WhatsApp)Email:sividi360@outlook.com