We developed a custom solution for the GA240.A126102 encoder, intended for applications where stable 13-bit parallel absolute position output must be maintained under industrial noise, discrete PLC input structures, and direct shaft mounting conditions. This configuration is based on the GA240 singleturn parallel absolute encoder platform, using a clamping flange, Ø10 mm solid shaft, 10–30 VDC supply, and binary push-pull output. It is not a serial interface device and it is not tolerant of loose control logic. It is a parallel data system where STORE, ENABLE, UP/DOWN, and Zero setting must be integrated correctly or the position word becomes unreliable. Typical production lead time: 15 working days.
Custom Solution Photos


Stable operation depends on shaft alignment, flange rigidity, connector integrity, and clean parallel signal handling.
System Limits
- No STORE signal during readout → position data can change during sampling
- ENABLE not held active → outputs switch to high-impedance and appear lost
- Weak shielding or noisy parallel wiring → bit errors and unstable absolute values
The GA240 platform is a 13-bit optical singleturn parallel encoder with 8192 steps per turn, push-pull short-circuit-proof outputs, and permanent code continuity check. Its core value is not bus communication but deterministic parallel data output. That also defines its main weakness: if the controller does not latch data correctly or if the 13 data lines are exposed to interference, the system may show false position values even though the encoder itself is still rotating normally.
This model uses binary code, which is straightforward for direct PLC interpretation, but binary output is also less tolerant of asynchronous bit transitions than Gray code. For that reason, the STORE line is not optional in serious control systems. The datasheet explicitly states that reliable data readout in binary code requires this line.
Installation and Wiring Constraints
- Use rigid clamping flange mounting and maintain proper shaft alignment
- Use the STORE input to latch data before reading
- Keep ENABLE at active low during output operation
- Define UP/DOWN correctly to match the real shaft direction
- Return Zero setting to GND after setting for best interference immunity
- Shield all D0 to D12 data lines and control lines in noisy environments
Failure boundary:
- Missing STORE logic → unstable binary readout
- ENABLE high → no usable output
- Wrong UP/DOWN logic → reversed position behavior
- Poor shielding → corrupted parallel word
- Excess shaft load or misalignment → reduced mechanical reliability
Replacement and Interface Mapping
- Suitable for systems requiring 13-bit binary parallel absolute position feedback
- Applicable where clamping flange mounting and Ø10 mm shaft are required
- Not suitable where serial interfaces are expected or where parallel timing cannot be controlled
- Best used in control systems that can manage latch, enable, and direction logic correctly
Key Data
- Model: GA240.A126102
- Type: Singleturn absolute encoder, parallel
- Sensing method: Optical
- Resolution: 13 bit / 8192 steps
- Code: Binary
- Output circuit: Push-pull, short-circuit proof
- Supply voltage: 10–30 VDC
- Initializing time: typ. 20 ms
- Accuracy: ±0.025°
- Shaft: Ø10 mm solid shaft
- Flange: Clamping flange
- Max speed: ≤10000 rpm mechanical / ≤6000 rpm electrical
- Shaft load: ≤20 N axial / ≤40 N radial
- Protection: IP54 without shaft seal / IP65 with shaft seal
- Operating temperature: -25 to +85 °C
- Housing: Ø58 mm aluminium
GA240.A125102 Absolute Encoder
GA240.A12C102 Encoder Solution
GA240.A12C002 Industrial Encoder
GA240.A106102 Absolute Encoder Solution